Download Wind sensor static WSS REC DATA SHEET

Transcript
Data sheet
Wind Sensor Static WSS REC
Technical specifications
The sensor is designed according to the standards below
12V or 24V DC
Power supply
(9.0…31.2V DC)
With inactive heating element:
<0.1W
Power consumption
With automatic heating at maximum: <15W
RS485 bus:
The bus should be terminated with 120 to 200 ohm for pure RS485
operation
RS422 bus:
For single listener connection on RS422, the data line must be terminated
with a 200 to 250 ohm resistor to obtain the necessary output
Interface
Data sentence
Wind speed
Wind direction
Update interval
Start-up time
Connection
Mounting
Compass safety
distance
Protection
Relative humidity
Pressure
Temperature
Vibration test
Safety
EMC
Housing
Weight
Dimensions,
cardboard box
DEIF A/S
Standards
Hardware settings:
These are the RS485 hardware settings:
Baud rate: 4800 bps
Data:
8 data bits
Parity:
None parity
Stop:
1 stop bit
Flow control: No flow control
NMEA 0183:
$WIMWV – Wind speed and direction data
$WIXDR – Transducer measurement response
NMEA 0183 ver. 3.0
$WITXT – Error messaging
For details, see the Appendix to User's Manual, WSS REC, document no.
4189350038.
Range:
0….60m/s
Resolution: 0.1m/s
Accuracy: 0…35m/s: ±0.3m/s or ±3%, whichever is greater
>36m/s: ±5%
o
Range:
0…. 360 continuously
o
Resolution: 1
Accuracy: ±3% in relation to wind direction
1 sec.
<5 sec. from power on to valid data output
10 metres 4 x 0.75mm2 screened cable type UL2464
18AWG/4C+DW+AL/MY+Jacket
The 10m cable is fixed on the sensor and is open-ended
¾” pipe thread: Outer diameter: 1.04 inches (26.4mm), 14 threads per inch
0.2 metres (8 inches)
IEC 945 and EN 60945
IP66
0…. 100%
600…1100hPa
Operating range: -52…+60 °C (class approved for: -25…+60 °C)
Storage:
-60…+70 °C
IEC 529 and EN 60529
EN/IEC 60068-1/2
3…13.2Hz:
2mm (peak-peak)
13.2…100Hz: 0.7g
3…15Hz:
+2.5mm (peak)
15…50Hz:
2.3g
Cat. III, poll. dg. 2, 550V AC rms, 50Hz, 1 minute
CE-marked for industrial environment
Wind sensor housing: Polycarbonate +10% glass fibre
Mounting tap:
Corrosion-resistant stainless steel
0.8kg
EN 60051
EN 60945,
EN/IEC60068-2-6 and
DNV Class A
GL curve 4 for masts
EN 61010-1
EN 61000-1-1/2/3/4
UL94 V0
450 x 315 x 230mm
Page 3 of 5