Download Wind sensor static WSS REC DATA SHEET
Transcript
Data sheet Wind Sensor Static WSS REC Technical specifications The sensor is designed according to the standards below 12V or 24V DC Power supply (9.0…31.2V DC) With inactive heating element: <0.1W Power consumption With automatic heating at maximum: <15W RS485 bus: The bus should be terminated with 120 to 200 ohm for pure RS485 operation RS422 bus: For single listener connection on RS422, the data line must be terminated with a 200 to 250 ohm resistor to obtain the necessary output Interface Data sentence Wind speed Wind direction Update interval Start-up time Connection Mounting Compass safety distance Protection Relative humidity Pressure Temperature Vibration test Safety EMC Housing Weight Dimensions, cardboard box DEIF A/S Standards Hardware settings: These are the RS485 hardware settings: Baud rate: 4800 bps Data: 8 data bits Parity: None parity Stop: 1 stop bit Flow control: No flow control NMEA 0183: $WIMWV – Wind speed and direction data $WIXDR – Transducer measurement response NMEA 0183 ver. 3.0 $WITXT – Error messaging For details, see the Appendix to User's Manual, WSS REC, document no. 4189350038. Range: 0….60m/s Resolution: 0.1m/s Accuracy: 0…35m/s: ±0.3m/s or ±3%, whichever is greater >36m/s: ±5% o Range: 0…. 360 continuously o Resolution: 1 Accuracy: ±3% in relation to wind direction 1 sec. <5 sec. from power on to valid data output 10 metres 4 x 0.75mm2 screened cable type UL2464 18AWG/4C+DW+AL/MY+Jacket The 10m cable is fixed on the sensor and is open-ended ¾” pipe thread: Outer diameter: 1.04 inches (26.4mm), 14 threads per inch 0.2 metres (8 inches) IEC 945 and EN 60945 IP66 0…. 100% 600…1100hPa Operating range: -52…+60 °C (class approved for: -25…+60 °C) Storage: -60…+70 °C IEC 529 and EN 60529 EN/IEC 60068-1/2 3…13.2Hz: 2mm (peak-peak) 13.2…100Hz: 0.7g 3…15Hz: +2.5mm (peak) 15…50Hz: 2.3g Cat. III, poll. dg. 2, 550V AC rms, 50Hz, 1 minute CE-marked for industrial environment Wind sensor housing: Polycarbonate +10% glass fibre Mounting tap: Corrosion-resistant stainless steel 0.8kg EN 60051 EN 60945, EN/IEC60068-2-6 and DNV Class A GL curve 4 for masts EN 61010-1 EN 61000-1-1/2/3/4 UL94 V0 450 x 315 x 230mm Page 3 of 5