Download VSP 112W User Manual
Transcript
Cable Length 15m Protection Grade 5m IP67 SER510R/T Communication Protocol 1. SER510R/T adopts standard DB9 interface, with serial asynchronous communication mode, baud rate is 9600, start bits is 1, data bits is 8, 1 stop bits is 1, no parity bit. Pin Description: 2------->TXD 3<-------RXD 5<-----> GND 7------->VDD+5V 2. Data protocols, the sensor will send the brightness and temperature that collected every second, the formats are as follows: Header (12 bytes) Effective Brightness Brightness E5 B2 41 FF 02 00 0A 1 byte Effective Temperature Checksum 2 bytes 2 bytes Temperature 2 bytes 1 byte 00 73 6E 72 3A Header is for fixed 12 bytes Effective Brightness: 01: Effective brightness 00: Invalid brightness Brightness: High byte front, low byte behind, attenuation coefficient of the cover is about 3.3. Maximum value of brightness: FFFE, and FFFF means brightness is overflow. The brightness value of the sensors return multiplied by 3.3 is the current unique degree of brightness (lx). Effective Temperature: 01: Effective temperature 00: Invalid temperature Temperature: High byte front, low byte behind. Integer part of temperature is divide the value by 10, and the decimal part is remainder. The highest bit is 1 when the temperature is below zero, and the unit of the temperature is Celsius degrees. Checksum: Including all the header bytes plus 1. Data example: E5B2 41FF0200 0A00736E 723A0107 C6010136 8AFA E5B2 41FF0200 0A00736E 723A0107 5C010133 F7FA VSP 112W User Manual 125