Download User Manual

Transcript
SKOPE Pegasus Horizontal 1/1 Gastronorm Integral Prep Chiller
Refrigeration Unit Wiring Component Key
Models: UE50/60ACD
Item Description
Item Description
1
Refrigeration Unit Assembly
23
Programmed Electronic Controller
2
Unit Wiring Junction Box
24
Evaporator Box Assembly
3
Refrigeration Unit Supply Isolation Flex (with 3-pin blue free
ENSTO plug fitted)
25
Evaporator Box Exterior Earth Connection
4
3-Pole Blue Free ENSTO Plug
26
Terminal Box (for evaporator fan flex extension)
5
Isolation Flex Earth Connection
27
Evaporator Fan (CW rotation - LE* for LH refrigeration unit,
CCW rotation - LE* for RH unit).
6
7-Pole Terminal Block
28
Thermal Cutout
7
Electronic Controller Module
29
Defrost Element (182W at 230V)
- 2 for UE50FAC refrigeration unit
- 3 for UE60FAC refrigeration unit
8
Electronic Controller Connection Cable
30
Defrost Sump Element (312W at 230V)
9
High Pressure Switch (auto-reset)
31
Cabinet Ambient Temperature Probe
10
Cabinet Supply Fuse (3A)
32
Evaporator Coil Temperature Probe (red sleeve)
11
4-Pole Panel Mount ENSTO Socket
33
Condenser Assembly
12
2-Pole Terminal Block
34
Condenser Assembly Earth Connection
13
Inline Insulator (for unused terminal)
35
Compressor
14
3-Core Compressor Supply Flex
36
Compressor Winding Protector / Thermal Overload
15
OMRON Latching Relay
37
Compressor Main Winding
16
Evaporator Fan 4-Core Extension Flex
38
Compressor Starting Relay
17
Evaporator Fan Capacitor
39
Compressor Start Winding
18
Condenser Fan 4-Core Extension Flex (with 4-pole ENSTO
socket fitted)
40
Compressor Starting Capacitor
19
Condenser Fan Capacitor
41
Condenser Fan (with 4-pole ENSTO plug fitted) (CW
rotation - LE*)
20
Unit Wiring Junction Box Cover Earth Connection
42
4-Pole Free ENSTO Plug
21
Electronic Controller Enclosure Ass’y
43
4-Pole Free ENSTO Socket
22
Electronic Controller Enclosure Earth Connection
Servicing
User Manual
21