Download Bench Shipping Scale
Transcript
SECTION 1 INTRODUCTIONS 1.1 Introduction The indicator provides an accurate, fast and versatile series of general purpose weighing indicator with counting, check-weighing, animal weighing functions and preset tare. 1.2 Specification plastic housing Housing 110V 50/60Hz Power supply built-in rechargeable battery. Display 6 digits Max input 15mV ADC Σ-Δ External 1/30000 Resolution Interface RS-232 Output Stabilisation time 1 second typical Operating 0°C - 50°C / 32°F - 104°F temperature Load cell 6V4AH. 1’LED. drive voltage 5V/ Max 150mA Other function Real-time clock and units conversion Load cells Up to eight 350 ohms cells 1.3 Installation The weighing indicator should be sited in a location accuracy would not be degraded. Avoid extremes of temperature. Avoid unstable power sources. Do not use near large users of electricity such as welding equipment or large motors. Verify the voltage showing on the label matches the voltage in your area. connection of loadcell: Plastic housing connect to Din9 Pin6 +E Pin1 -E Pin9 +S Pin8 -S Pin5 shield connection of RS232 Plastic housing connect to Din9 Pin 2 TXD Pin3 RXD Pin5 GND SECTION 2 KEY DESCRIPTIONS SOFT POWER ON/OFF Key Power on/off the indicator. ZERO Key 1) When self-checking, Press ZERO Key to enter parameter setting; 2) Set the zero point for all-subsequent weighing; -2-