Download WinView/32 Software User`s Manual

Transcript
Chapter 14
Pulser Operation
145
further apart but much wider to accommodate the lower signal amplitude. The result
is output data that is relatively constant in intensity over the decay time. This data can
be easily normalized by dividing each point by the exposure time and then using a
spline fit to recover the curve. The logarithm (base e) can then be taken to obtain a
straight line (or two lines successive line segments, each with a different slope for
two species). Tangents can be fitted to each segment to determine the rate constant
for each species.
Fast Decay
Time Constant: In a two species system, enter the decay time of the faster of the two
species. Note that it is not essential that you enter a value. If you have the decay time
information, you will get better data if the information is entered, but acceptable results
can be obtained in many situations by using the default. If there is only one species, or
if you want to discard the fast decay process, simply enter zero for the Amplitude.
Note that the Gate Width and Gate Delay values need to be selected with some care
in fluorescence decay experiments. Typically the starting gate width will be very
narrow, perhaps 2 ns, and the final gate width should be wider by about the ratio of
the anticipated signal amplitude decrease over the course of the measurement
timebase. Similarly, the starting gate delay has to take the various insertion delays
into account, and the final delay value might typically be set to a value on the order
of five times the anticipated decay time of the process.
Amplitude: This is the relative amplitude of the fast decay with respect to the slow one.
For example, if you know that the amplitude of the fast decay signal is typically five
times the amplitude of the slow decay signal, you could enter "5" for the fast decay
amplitude and "1" for the slow decay amplitude. Keep in mind that it is the ratio that is
being expressed. For example, there is no difference between entering fast and slow
amplitude values of "5" and "1" and entering fast and slow amplitude values of "50" and
"10." Note that the default values will give satisfactory results in many measurements.
Slow Decay
Time Constant: In a two species system, enter the decay time of the slower of the
two species. Note that it is not essential that you enter a value. If you have the decay
time information, you will get better data if the information is entered, but acceptable
results can be obtained in many situations by using the default. If there is only one
species, or if you want to discard the fast decay process, simply enter zero for the fast
decay Amplitude.
Amplitude: This is the relative amplitude of the slow decay with respect to the fast
one. For example, if you know that the amplitude of the slow decay signal is
typically one-fifth the amplitude of the fast decay signal, you could enter "1" for the
slow decay amplitude and "5" for the fast decay amplitude. Keep in mind that it is the
ratio that is being expressed. For example, there is no difference between entering
slow and fast amplitude values of "1" and "5" and entering fast and slow amplitude
values of "10" and "50."