Setup software (version PROFIBUS)
2.8
Version 04/08
Screen page «digital I/O X3»
Cycle time of the digital I/O functions approx. 1 ms.
The states of the digital inputs/outputs are shown in the diagram of the connector X3.
2.8.1 Digital inputs DIGITAL-IN1 / DIGITAL-IN2 / PSTOP / NSTOP
The terminals DIGITAL-IN1/2, PSTOP and NSTOP (X3/11,12,13,14) can be used in combination with
internal functions. Changes can only be made if the output stage is disabled, followed by a reset.
The zero pulse initiator must be applied to a digital input. Function 12, Reference, must be
assigned to the respective input.
Function can be combined with
ID
Function
0
1
2
3
4
5
6
7
12
13
15
18
20
23
24
25
27
32
Off
Reset
PSTOP
NSTOP
PSTOP+Intg.off
NSTOP+Intg.off
PSTOP+NSTO
P/Nstop+Intg.of
Reference
ROD/SSI
Start_MT Next
Ipeak2x
Start_JOG x
Start2_MT No.x
OPMODE A/B
Zero_latch
Emerg.Stop
Brake
Active edge
#
$ (Low active)
$ (Low active)
$ (Low active)
$ (Low active)
$ (Low active)
$ (Low active)
#
High/Low
Can be set
#
#
#
High/Low
#
#
#
Auxiliary
value
% of Ipeak
v in µm/s
see descrip.
-
DIGITAL DIGITAL
IN1
IN2
X3/11
x
x
X3/12
x
PSTOP
NSTOP
X3/13
X3/14
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
2—26