Download Final Report - Electrical and Computer Engineering

Transcript
Relays
Relays were chosen based
primarily on cost. Given
that a standard household
circuit breaker is rated for
15A and that the purpose of
our project is to switch
devices that draw almost
this amount of current, the
relays themselves had to be
rated similarly. This meant
handling both soft and hard
loads (resistive and mixed
resistive/inductive) up to
15A. Additionally the
relays had to be rated for
use on the 120V AC line
voltages used in North
American household
Figure 3: Relay
electrical systems. In order
to market the product
internationally this rating must be increased to 240V AC. For the prototype a relay rated
for 30A resistive load at 240V AC from Tyco's (Potter & Brumfield) T9A series was
used.
The T9AS1D12-5 has a minimum coil voltage of 5V and pulls approximately 180 mA at
this level from our testing. This makes direct switching by the Arduino or XBee
impossible as the outputs of these devices are rated for less than 25mA. The solution to
this problem is to use a transistor based relay drive circuit as shown in Figure 4 below.
Unfortunately,
these relays are
only rated for
100,000
operations,
corresponding to a
lifetime of only
2.85 years if used
to switch a load
on and off in 15
Figure 4: Transistor based relay
6