Transcript
DeviceNet TM Object Model Assembly Object (04HEX - 2 Instances) The following tables contain the attribute, instance, data mapping, and common services information for the Assembly Object. Table 2-6 Assembly Object (04 HEX - 2 Instances) Instance Attribute Name DeviceNet TM Data Access ID Data Type Value Rule Class 1 Revision UINT 2 Get (Instance 0) 2 Max instance UINT 0x81 Get Instance 1 100 Input index USINT 0x64 Get/Set Input size (in bytes) UINT 0x00 Get 101 102 Output index USINT 0x70 Get/Set 103 Output size (in bytes) UINT 0x00 Get Input 3 Input Get Byte Data Field 0-3 T->O dynamic assembly point instance 1 Instance 0X64 4-7 T->O dynamic assembly point instance 2 ... 248-251 T->O dynamic assembly point instance 63 251-255 T->O dynamic assembly point instance 64 Output 3 Output Get/Set Instance 0X70 0-3 O->T dynamic assembly point instance 1 4-7 O->T dynamic assembly point instance 2 ... 248-251 O->T dynamic assembly point instance 63 251-255 O->T dynamic assembly point instance 64 *These valves are stored to NVRAM. Table 2-7 Assembly Output instance data mapping Data Component Class Name Class Number Name Instance Number Attribute Number Table 2-8 Assembly Input instance data mapping Data Component Class Name Class Number Name Instance Number Table 2-9Assembly Object’s common services ServiceImplemented for Service Code Class Level Instance Level Name 0EHex Yes Yes Get_Attribute_Single 10 Hex No Yes Get_Attribute_Single 22 © 2010, ROSS CONTROLS®. All Rights Reserved. Attribute Number