Download User Manual
Transcript
This operating manual ФВКМ.412113.017РЭ covers design, operating principal, characteristics of the product and indications necessary for proper and safe use of the product (intended use, maintenance, routine repair, storage and transportation), and also information about utilization of the product. 1 DESCRIPTION AND OPERATION OF THE PRODUCT 1.1 Product designation The clinical X-ray dosimeter DRK-1 ФВКМ.412113.017 (henceforth referred to as the dosimeter) is manufactured in compliance with the requirements of the technical conditions TU 4362-004-31867313-98, and intended to: - measure the product of absorbed dose in air and cross-section area of an X-ray beam at the X-ray machine output (henceforth referred to as the dose-area product); - estimate the effective dose to the patient during X-ray diagnostics and roentgenotherapy, using the appropriate procedures; - control consistency of operation of X-ray machines in the course of their use. The dosimeter is a fixed lab measuring instrument, and is used in medical institutions for all basic types of Russian and foreign X-ray machines (radiological, photofluorographic, surgical, angiographic, mobile), except for dental, mammographic and tomographic X-ray machines. The dosimeter has an integrated printer to print measurement results on a paper tape. The dosimeter may be used with two ionization chambers at once. With this, the second ionization chamber operates in the accumulation mode as well as an independent measuring channel. The dosimeter has a feature of data transfer through information links, and provides access to the processed data via the RS-232 interface-based links. 1.2 Technical features 1.2.1 Operating range of anode voltages of the X-ray emitter is 30 to 200 kV. 1.2.2 Range of the detected dose-area product ...…………………….………...1 to 104 cGycm2. 1.2.3 Limits of a relative intrinsic error of the dose-area product measurement for a confidence probability of 0.95 ………...…………………………………………………………….. (15+35/D) %, where D is a non-dimensional quantity that is numerically equal to the dose-area product value in cGycm2. 1.2.4 Dependence of the dosimeter sensitivity on radiation energy in the operating range of anode voltages of the X-ray emitter ……………..……………………………... no greater than 25 %. 1.2.5 The dosimeter sensitivity 1 min later after power-up differs from this 15 min later after power-up for ……….………..……………………………………..…………….. no greater than 10 %. 1.2.6 Change of the dosimeter sensitivity depending on the irradiated area … no greater than 5 %. 1.2.7 Dependence of the dosimeter sensitivity on absorbed dose rate ….... no greater than 10 %. 1.2.8 Uniformity of the dosimeter sensitivity over the ionization chamber area.… no less than 95 %. 1.2.9 Leakage current of the ionization chamber provides the reading increment for 1 h of work in the absence thereof an external radiation exposure …..………………….. no greater than 1 cGycm2. 1.2.10 Transparency of the ionization chamber for visible light …..….……...…...… no less than 70 %. 1.2.11 Attenuation equivalent of the ionization chamber at the anode voltage of 100 kV, percentage ripple of the production voltage is no greater than 10 % of the overall filtration of 2 mm ………………………………………………………………………. no greater than 0.5 mm Al. 1.2.12 Warm-up time .…….……………..…………………………...….. no greater than 1 min. 1.2.13 Measurement of the dose-area product using the dosimeter is synchronized with work of the X-ray machine, with this, continuous operation time ……………………………… no less than 6 h. ФВКМ.412113.017РЭ 3