AT Command Manual for GR64 & GS64
subscriber without provision of CLIR in permanent mode the network will act according
GSM 02.81.
The setting shall be per logical channel.
When the MS is turned off and then turned on again the
Parameter Setting
<n> shall turn
back to default, i.e. the presentation of CLI shall be used according to the subscription of
the CLIR service, <n> is 0.
Read command gives the default adjustment for all outgoing calls (given in <n>), and
also triggers an interrogation of the provision status of the CLIR service (given in <m>).
Test command returns values supported by the TA as a compound value.
On a per call base CLIR functionality is explained in subclause “ITU-T V.25ter dial
command”.
Defined values:
<n>
Description
Presentation indicator is used according to the subscription of the
0
CLIR service
1
CLIR invocation
2
CLIR suppression
<m>
Description
0
CLIR not provisioned
1
CLIR provisioned in permanent mode
2
Unknown (e.g. no network)
3
CLIR temporary mode presentation restricted
4
CLIR temporary mode presentation allowed