D. Repeat Exercise C comparing the
results for =30 to those of a= 0 and a=
20. If the ramp series maneuver in Step 14 resulted
in a Limit Exceeded
condition, can you
explain why?
E. Explain why
cross-coupling is not expected when
q2 = 0, q3 = 0 and is
expected
whenever q2 ≠ 0, q3 ≠ 0. Make your explanation in terms of
the structure of the controller (Figure 6.7-1) and the nature of the plant
equations of motion
(you need only consider the Eq’s 5.4-9, -10,
& -11,
and 5.3-4 &-5 in your answer.)
6.8 Multivariable Control in Dynamically Coupled
Configurations
In this
section, we employ full multi-variable control of the plant
while in nonzero gimbal axis orientations of {q2o = 20o,
q3o = -20o} and {q2o = 30o, q3o = -30o}. As was seen in the previous section, the
cross coupling between the inputs and
outputs – as compared with
the decoupled case of {q2o = 0, q3o = 0}– increases
with these gimbal angles. The state
space block diagram
of the control scheme is shown in Figure
6.7-1. The initial tests in this
section are performed with
the apparatus in the configuration of Figure 6.7-2.
Figure 6.8-1. Multivariable System Block
Diagram