Download OPERATION MANUAL Position Control Units - Support
Transcript
Functional upgrade Establishing connections when there are unconnected axes or axes with alarms that cannot be cleared Unit version 1.2 If any of the axes registered in the scan list are not connected, have the control power supply interrupted, or have an alarm that can be reset only by cycling the power supply, an MLK initialization error (Unit error code 0020 (hex) will occur after the connections are established and operations using MECHATROLINK communications will not be possible any axes, including those without errors. To start MECHATROLINK communications normally, all errors must be cleared for all axes registered in the scan list before connections can be established. Unit version 1.3 Axis operations using MECHATROLINK communications are possible for any axes registered in the scan list and for which MECHATROLINK communications have been started (see note) regardless of whether there are Servo Drive alarms. If there are any axes with alarms, they will be indicated by the Error Flags and error code in the Axis Operating Input Memory Areas. If there are alarms in the Servo Drive that can be cleared only by recycling the power, they will be detected as Unit errors (MLK initialization errors) for Units with unit version 1.1 or earlier, but they will be detected in the individual axis areas. Note If R88D-WN@-ML2 W-series Servo Drives (Models with Built-in MECHATROLINK-II Communications) are connected, an encoder communications error (A.C9@) will occur in the Servo Drive and it will not be possible to start MECHATROLINK communications for Units with unit version 1.3 or earlier. Transferring parameters when Servo parameters cannot be transferred there are axis errors (i.e., written, read, or saved) for axes with errors. The errors must first be reset to clear the axis error status before Servo parameters can be transferred. (Refer to 6-3-2 MECHATROLINK Communications Status.) Servo parameters can be transferred (i.e., written, read, or saved) for axes with errors. If the axis error already exists, it will not be overwritten even if an error occurs during parameter transfer. If Servo parameters are written when there is an axis error, be sure to confirm that the parameters were transferred correctly. Locking the servo when a software limit is being detected for a Motor with an absolute encoder If an attempt is made to lock the Servo when an absolute encoder is used, the software limits are enabled, and the present position is within the software limit area, a software limit error will occur and the Servo lock operation will be canceled. (Refer to 5-3 Transferring Servo Parameters.) The Servo can be locked at any position, regardless of the type of encoder and the software limit settings. (Refer to 10-8-4 Software Limit Operation.) To lock the Servo in the above situation, the software limit must first be disabled. xv
Related documents
G Series Servomotors/Drives w/Mechatrolink
Axis 2400+ Instruction manual
Raymarine Satellite TV Systems User`s guide
CS1W-NC 71 - OMRON Industrial Automation
Sigma-II Series SGDH MECHATROLINK-II - Support
FX-PCS/WIN-E SOFTWARE MANUAL
D-V4 CX-Motion-NCF Ver. 1.9 Operation Manual
SmartPilot X-5 - Busse Yachtshop
Sigma-II Series SGDH MECHATROLINK
User Manual for the Third-Generation, Advanced Piston Corer
SGDS Sigma III Servo Amplifier User Manual for Mechatrolink
OPERATION MANUAL