Download Volume 3 Section 2

Transcript
Chapter 11
Communication and Traffic Controls Equipment
Volume 3 Section 2
Part 3 BA 72/03
11. COMMUNICATION AND TRAFFIC CONTROLS
EQUIPMENT
General
11.1 This Chapter provides general guidance on
maintenance of any communication cables, telephones,
radio systems, closed circuit televisions and variable
message signs that are not included in the RMC or
NMC contracts, see Chapter 2. Reference should also
be made to Chapter 7 for maintenance of mechanical
supporting systems.
11.2 In England, maintenance of the NMCS is detailed
in the Highways Agency’s Motorway Communications
(MC) series of document which take precedence over
tunnel documentation. Key documents are listed in the
Reference Chapter.
Communication Cables
Description of Typical Equipment and Access
Arrangements
11.3 Communications cables in the tunnel bore, tunnel
service buildings, sumps and drawpits are covered
within this Chapter.
Cleaning
11.4 Typically, no cleaning of the cabling is required.
Inspections should be carried out on all accessible
cables at intervals typically of 3 months noting any
signs of damage, corrosion or similar defects. Typically
no routine servicing is required
Telephone Systems
Description of Typical Equipment and Access
Arrangements
11.5 The provision of telephone systems varies from
one tunnel to another, and historically has been
determined largely by the requirements of the tunnel
operator and the local police and fire service.
11.6 Up to three separate systems may be provided,
fulfilling the following functions:
i.
an emergency telephone system, to enable the
public to summon assistance in the event of an
incident;
May 2003
ii.
a smoke control telephone system, to enable the
fire service to communicate between one end of
the tunnel and the other;
iii.
an internal telephone system, for use by
maintenance staff.
Cleaning
11.7 The telephone set should be cleaned at the same
interval as testing, but is currently carried out monthly
for the National Network (ref MCH 1743).
Inspection
11.8 Visual inspection for defects and correct number
labelling should be carried out at the same interval as
testing.
Service
11.9 Generally, the telephone systems require no
servicing.
Testing
11.10 Typically testing of all aspects of operation of the
emergency telephones should be carried out at intervals
of one week, and of other telephones at intervals of 3
months. Battery supplies to the telephones should be
tested at intervals of one year.
Radio-Relay Systems
Description of Typical Equipment and Access
Arrangements
11.11 A typical tunnel radio-relay system comprises a
leaky feeder antenna through each bore of the tunnel,
linked to a number of transceivers in a tunnel service
building. For optimum signal quality, the transceivers
are normally linked to the appropriate users’ remote
base stations by landlines, so that the tunnel system
behaves as an additional transmitter/receiver on the
local area communications network.
11.12 In cases where a landline connection from the
tunnel service building is not feasible, an external
antenna may be located near the tunnel to receive
11/1