Download Volume 3 Section 2
Transcript
Chapter 11 Communication and Traffic Controls Equipment Volume 3 Section 2 Part 3 BA 72/03 11. COMMUNICATION AND TRAFFIC CONTROLS EQUIPMENT General 11.1 This Chapter provides general guidance on maintenance of any communication cables, telephones, radio systems, closed circuit televisions and variable message signs that are not included in the RMC or NMC contracts, see Chapter 2. Reference should also be made to Chapter 7 for maintenance of mechanical supporting systems. 11.2 In England, maintenance of the NMCS is detailed in the Highways Agency’s Motorway Communications (MC) series of document which take precedence over tunnel documentation. Key documents are listed in the Reference Chapter. Communication Cables Description of Typical Equipment and Access Arrangements 11.3 Communications cables in the tunnel bore, tunnel service buildings, sumps and drawpits are covered within this Chapter. Cleaning 11.4 Typically, no cleaning of the cabling is required. Inspections should be carried out on all accessible cables at intervals typically of 3 months noting any signs of damage, corrosion or similar defects. Typically no routine servicing is required Telephone Systems Description of Typical Equipment and Access Arrangements 11.5 The provision of telephone systems varies from one tunnel to another, and historically has been determined largely by the requirements of the tunnel operator and the local police and fire service. 11.6 Up to three separate systems may be provided, fulfilling the following functions: i. an emergency telephone system, to enable the public to summon assistance in the event of an incident; May 2003 ii. a smoke control telephone system, to enable the fire service to communicate between one end of the tunnel and the other; iii. an internal telephone system, for use by maintenance staff. Cleaning 11.7 The telephone set should be cleaned at the same interval as testing, but is currently carried out monthly for the National Network (ref MCH 1743). Inspection 11.8 Visual inspection for defects and correct number labelling should be carried out at the same interval as testing. Service 11.9 Generally, the telephone systems require no servicing. Testing 11.10 Typically testing of all aspects of operation of the emergency telephones should be carried out at intervals of one week, and of other telephones at intervals of 3 months. Battery supplies to the telephones should be tested at intervals of one year. Radio-Relay Systems Description of Typical Equipment and Access Arrangements 11.11 A typical tunnel radio-relay system comprises a leaky feeder antenna through each bore of the tunnel, linked to a number of transceivers in a tunnel service building. For optimum signal quality, the transceivers are normally linked to the appropriate users’ remote base stations by landlines, so that the tunnel system behaves as an additional transmitter/receiver on the local area communications network. 11.12 In cases where a landline connection from the tunnel service building is not feasible, an external antenna may be located near the tunnel to receive 11/1