Download IEC TEST REPORT FORM TEMPLATE

Transcript
Page 36 of 61
Report No. KTI14ES09002
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Supplementary information:
4.5.5
TABLE: Ball pressure test of thermoplastic parts
Allowed impression diameter (mm) ..................... :
Part
N/A
 2 mm

Test temperature Impression diameter
(mm)
(C)
Supplementary information:
4.7
TABLE: Resistance to fire
Part
P
Manufacturer of
material
Enclosure
Type of material
NamSun
Metal (Aluminium)
Thickness Flammability
(mm)
class
Evidence
2.5
Supplementary information:
5.1
P
TABLE: touch current measurement
Measured between:
L, N to Metal enclosure
supplementary information:
TRF No. IEC60950_1F
Measured
(mA)
Limit
(mA)
1.6
3.5
Comments/conditions