Download MLR: Electrical Study Guide
Transcript
MLR: Electrical Study Guide ©2013 Melior, Inc. Solenoid Pull-in Winding and Hold-in Winding Some solenoids have two separate windings: a pullin winding, and a hold-in winding. The pull-in winding has many turns of wire, and the hold-in winding has the same number of turns of smaller wire. The illustration shows both windings. Solenoid Windings As the ignition is turned to START, current flows from the battery to the S terminal on the solenoid, and through the hold-in winding to ground. Current also flows through the pull-in winding to the solenoid M terminal, and through the motor windings to ground. When the solenoid contacts are connected, there is equal voltage on both sides of the pull-in coil; thus, no current flows through that branch of the circuit. Diagnostically, if a hold-in winding fails, the pinion will engage repeatedly but it will not remain engaged. Likewise, a pull-in winding failure will prevent the pinion from engaging at all. On some starters, a pull-in winding failure will allow the motor to run, even if the pinion is not engaged. Reduction Starters On some starters, called reduction starters, extra gears are used to achieve even more reduction and develop higher torque. A planetary gearset or an idler gear arrangement provides the additional gear reduction. Page 69 of 88