Rules Large Vertex Gap [G-FA-VG] 8.20 Large Vertex Gap [G-FA-VG] Description This rule checks whether the distance between vertices and the underlying surface is within the given tolerance. Scope Documents: JT Items: JTBRep, XTBRep Parameter “Maximum allowed distance [mm]” Maximum allowed distance between vertices and the underlying surface. Marking elements Example Fig. 1: Marking elements for a large vertex gap. The red arrow indicates the measured distance between vertex and surface. The measured value of 0.028313 is greater than the maximum allowed distance. Transcat PLM 51 LiteComply 1.5.1