Download UCN-L

Transcript
®
MIEN006-04
5.3.
Pump-Motor Unit alignment
5.3.1. General Information
STOP
Pump and motor are connected through an elastic coupling, that can compensate
little alignment imperfections due to the assembly itself or caused by thermal
dilatation.
The elastic coupling is complete with sparkproof coupling-cover. Alignment
imperfections however must not exceed the limits specified below! An appropriate
alignment is extremely important for the correct life of the pump. CDR Pompe
S.p.A. always delivers aligned pump-motor units.
5.3.2. Alignment verification
STOP
Usually it is not necessary to re-align the pump-motor unit at site, if it has not been
damaged during transport or handling.
However, it is safer always to check the alignment before starting the pump or
after performing a maintenance service.
Warning: Always make sure that the motor has been switched off before
performing the alignment check.
CDR standard coupling are elastic with spacers. The only necessary instruments
in order to perform this check are a ruler and a thickness gage.
For different kinds of couplings further instruments might be requested. In that
case, please contact the coupling producers.
5.3.3. Angular Alignment
The 2 semi-couplings must be parallel to each other. In order to make sure that
they are properly aligned, measure the distance between the faces of the two
semi-couplings in 4 different points using a thickness gauge and make sure that
this distance remains always the same.
The maximum misalignment allowed is 0,5 mm (for a 100 mm diameter coupling).
Fig.6
CDR Pompe S.p.A. –UCN-L User Manual
Pag. - 17