Download User manual
Transcript
GB MH 3..7, MDH 3..7 Technical specifications Type MH 3 MDH 3 MH 4 MDH 4 MH 6 MDH 6 MH 7 MDH 7 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 l open outlet • / 0 (0) – • / 0 (0) – • / 0 (0) – • / 0 (0) – MPa (bar) closed outlet – •/1(10) – •/1(10) – •/1(10) – •/1(10) MPa (bar) Capacity system heating system IES system: bare resistance element required water resistance ≥ 800 Ω cm at 15 ° C electric supply Ω cm 230 ~ 230 ~ 230 ~ 230 ~ 230 ~ 230 ~ 400 2~ 400 2~ V nom. power rating @ 230/400V 3.5 3.5 4.4 4.4 5.7 5.7 6.5 6.5 kW nominal current 15.2 15.2 19.1 19.1 24.8 24.8 16.2 16.2 A req. min. cross-section 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 mm2 hot water output at ∆t = 25 K 2.0 2.0 2.5 2.5 3.3 3.3 3.7 3.7 l / min switching off @ 1.2 1.2 1.4 1.4 1.7 1.7 2.0 2.0 l / min weight filled with water approx. 1.2 1.3 1.2 1.3 1.2 1.3 1.2 1.3 kg dimensions (H x W x D) 13.2 x 18.7 x 8.0 protection class acc. to VDE 1 type of protection acc. to VDE approval marks IP 25: oversink units / IP 24: undersink units see rating plate 16 cm