TEST MODE
Entering Test Mode
(1) After the power is turned on and the initialization of the mechanism ("Initializing" is displayed) is completed, the following
indication is displayed.
The unit is in User mode.
(2) Set the door key to UNLOCK and press the FUNCTION key.
The following indication is displayed:
The unit enters System
Administrator mode.
(3) Press the FUNCTION and ±= keys simultaneously for 4 seconds.
The following indication is displayed:
Asking if you wish to enter Test
mode.
(4) Press the ENT key. The following indication is displayed:
The unit enters Test mode.
The cursor is blinking on D (Diag).
(5) Move the cursor to the mode of your choice by pressing the ±= or +≠ key, then press the ENT key.
Diag mode
• Select "Diag," then press the ENT key.
ENT
Diagnosis of each section
• Elevation Manual/Auto
(Elevation Manual operation mode/
Auto operation mode)
• Loading Manual/Auto
(Loading Manual operation mode)
• Flip-unit Manual/Auto
(Flip-unit Manual/Auto operation mode)
• Clamper Manual/Auto
(Clamper Manual operation mode)
• Mailslot Manual/Auto
(Mailslot Manual/Auto operation mode)
• Hyper-Mag. Manual/Auto
(Hyper magazine Manual/Auto operation
mode)
Step-by-step check of a series of operations
Selection of a slot and drive
ENT
ENT
Check of the disc out-of-position sensor
Adjustments of the front and rear
sensors are executed separately.
ENT
ENT
Check of the changer interface
Clamp motor, clamp switch
ENT
Clamping-completed signal,
Spindle-stop signal