Download WMS Reference Manual
Transcript
General Tools 2-35 The Flat Shade option generates an image with the hidden edges removed but it also applies colors to the triangles of a TIN. The Smooth Shade option is similar to the Flat Shade option except that a light source and Gouraud shading is used to make the TIN surface appear smoother. Shade The Shade command is used to generate a shaded image of a TIN or grid using the hidden surface removal technique, or a hill shade in plan view of a DEM in the Graphics Window. The default wire-frame image can be restored by selecting the Refresh command in the Display menu. Images can be "draped" over a TIN if properly registered. This is controlled in the Image Display Options by choosing to map the image to the TIN. If an image is mapped it will be draped and shaded over the TIN when choosing the Shade command. 2.10.5 Drawing Grid Options When entering new vertices or entering a polygon or polyline in plan view, it is often useful to have the coordinates snap to a uniform grid. This allows accurate placement of the objects when the desired coordinates are even multiples of some number. A drawing grid can be activated using the Drawing Grid Options command in the Display menu. If the Snap to grid option is selected, all new vertices will snap to the closest grid point. The grid spacing and options for displaying the grid can also be set using the Drawing Grid Options dialog 2.10.6 Auto vs. Manual Redraw When the Manual Redraw is on, all display refreshes must be done manually by either selecting the Refresh command in the Display menu or the Refresh macro from the tool palette. By default WMS is in Auto ReDraw mode which forces updates after display options change, or when a menu or dialog covers one of the graphics windows and there is not enough memory to save the pixels behind the menu/dialog so that they can be restored after the menu/dialog is dismissed. When in manual mode rather than forcing the will turn red, signifying that the display is not update, the Refresh macro up to date and refresh must be forced manually in order to bring it back up to date. The main advantage of using the manual redraw is when you are working on a computer that does not have enough video memory to do backing store and refreshes occur after each pull down menu disappears (typically only X-Window terminals have this problem).
Related documents
2711P-UM001C-EN-P, PanelView Plus Terminals User Manual
"user manual"
Reference Manual
Script Reference Manual
WIRSOS/STATEMOD Comparison - Wyoming Water Development
Groundwater Modeling System GMS v3.0 REFERENCE
TR-20 User Manual - NRCS Irrigation ToolBox
User Guide and Reference Manual
BOSS DAMBRK User`s Manual
HIVEL 2D v2.0
Document PDF disponible en téléchargement
Shopsmith 11" Specifications