M24/M27/M28 SWITCH ON/OFF A MEASURING PROBE
16.8 M24/M27/M28 Switch on/off a measuring probe
Before measurements can be performed with a remote signalling probe, e.g. an infrared probe, or a
hard wired probe, the probe must be switched on and after using the probe, it must be switched off.
M24 switch on the measuring probe (Measuring probe stands on the table)
M27 switch on the measuring probe (Measuring probe is mounted in the spindle)
M28 switch off the measuring probe
Format
Switch on a probe
M24
or
M27
Switch off a probe
M28
Notes and usage
Associated functions
G145, Measuring tool G600-G609
Activation
The function M27 is executed before the movements programmed in the same block, are executed
and M28 after the movements in the block.
Cancellation
The measuring probe is switched off with the function M28, the function M30 (end of program) or at
CLEAR CONTROL.
10-11-2003 V520
Programming Manual
489