Download Display - Service, Support
Transcript
SIJECT OP15B Screens 3.2.4 Injection screen Fig 3-37 Injection screen Operating sequences Press Injection key to enter the injection screen. See Fig 3-37. The system offers four Injection stages and three Pressure holding stages, and the transition between injection and pressure holding can be selected. On this screen, corresponding parameters can be set, such as position, pressure, flow and time. Injection 1 (Inject 1) set the position, pressure and flow of injection 1. Injection 2 (Inject 2) set the position, pressure and flow of injection 2. Injection 3 (Inject 3) set the position, pressure and flow of injection 3. Injection 4 (Inject 4) set the position, pressure and flow of injection 4. The time is set for the whole injection actions Transfer mode (TraMode) it refers to the transfer mode between injection and pressure holding. Three modes can be selected: Position mode, Time mode, and Position/Time mode. Holding 1 set the pressure, flow and time for pressure holding 1. Holding 2 set the pressure, flow and time for pressure holding 2. Holding 3 set the pressure, flow and time for pressure holding 3. Screw position (ScwPos) Press Manual injection key Decompression key SIJECT 16i Operation Manual display the current position of screw. to do injection once manually, and press to suck back once. 3-43