Chapter 5 Program Interrupt Instructions 45 MOVE b 46 LOCK 20;Defer any REACTions to "alarm" 47 MOVE c 48 MOVE d 49 LOCK 0;Allow REACTions 50 MOVE e 51 52 ; Disable monitoring of signal 1001 53 54 IGNORE −1001 55 . If signal 1001 transitions during execution of step 43, step 43 will complete, the subroutine alarm will be called, and execution will resume at step 44. If signal 1001 transitions during execution of step 47, steps 47, 48, and 49 will complete (since the program had been given a higher priority than REACT), the subroutine alarm will be called, and execution will resume at step 50.1 REACTE REACTE enables a reaction program that is run whenever a system error that would cause program execution to terminate is encountered. This includes all robot errors, hardware errors, and most system errors (it does NOT include I/O errors). Unlike REACT and REACTI, REACTE cannot be deferred based on priority considerations. The instruction: REACTE trouble will enable monitoring of system errors and execute the program trouble whenever a system error is generated. 1 The LOCK instruction can be used to control execution of a program after a REACT or REACTI subroutine has completed. V+ Language User’s Guide, Rev A 137