Section 3 – Installing the Control (+) 10 (+) 11 (-) ZONE 1 SMOKE 2k EOLR 2-WIRE SMOKE DETECTOR (-) Figure 3-10: 2-Wire Smoke Detector on Zone 1 Using 4-Wire Smoke Detectors on Zones 1-8 You may use as many 4-wire smoke detectors as can be powered from the panel's Auxiliary Power output without exceeding the output's rating (750mA). • NFPA limits the number of 4-wire smoke detectors to 18 per zone. • Auxiliary power to 4-wire smoke detectors is not automatically reset after an alarm, and therefore must be momentarily interrupted using either the J7 smoke detector reset output trigger or a 4204 Relay Module. Compatible 4-Wire Smoke Detectors Use any UL Listed 4-wire smoke detector that is rated for 10-14VDC operation and that has alarm reset time not exceeding 6 seconds. Some compatible 4-wire smoke detectors are listed below. Detector Type Photoelectric, direct wire Photoelectric w/heat sensor, direct wire Detector Model # System Sensor 4W-B System Sensor 4WT-B Wiring 4-Wire Smoke Detectors UL Power to 4-wire smoke detectors must be supervised with an EOL device (use a System Sensor EOLR-1 EOL relay module connected as shown in Figure 3-11). To wire 4-wire smoke detectors to zones 1-8, perform the following steps: Step Action 1 Select 4-wire smoke detectors (see list of compatible detectors shown previously). 2 Connect detectors (including heat detectors, if used) across terminals of the zone selected. All detectors must be wired in parallel. See Figure 3-11. NOTE: If you are using the J7 output trigger to reset the smoke detectors, refer to Smoke Detector Reset later in this section for the wiring instructions. 3 Connect the EOLR at the last detector in the loop across the zone’s terminals. You must connect the EOLR across the loop wires at the last detector. TO AUXILIARY POWER TERMINALS _ _ + 4-WIRE SMOKE DETECTORS + NOTES: · PROGRAM THE RELAY TO TRANSFER ON FIRE ZONE RESET (ACTIVATION CODE 54). SEE 4204 RELAY MODULE SECTION FOR DETAILS. · SECOND CODE AND OFF ENTERED AT CONSOLE MOMENTARILY INTERRUPTS DETECTOR POWER. + _ NO CONNECTION C NC _ + EOL POWER SUPERVISION RELAY MODULE A77-716B SHOWN POWERED. RELAY OPENS WHEN POWER IS LOST. NO RESET HEAT DETECTOR RELAY 1, 2, 3, OR 4 4204 RELAY MODULE + 2k EOLR _ TO FIRE ZONE TERMINALS V128BP-002-V0 Figure 3-11: 4-Wire Smoke Detectors Using 2-Wire Latching Glassbreaks on Zone 8 Zone 8 can support 2-wire glassbreak detectors. The zone provides enough standby current to power up to 50 2-wire glassbreak detectors meeting the requirements listed below. 3-9