Mx2wire+ User Manual: Installation
2.7 Installation with On-Wall Socket
Supplied cable plugs
For cables of 3–5 mm
1. Prepare the on-wall socket: Use the supplied drilling
template for the on-wall socket (fold-out at the end of
this manual) to mark the precise position of the drill
holes and the cable guide. Make sure that the alignment
and position of the socket in relation to the two-wire
cable are correct (TOP / OBEN arrow).
For cables of 5–7 mm
For cables with a
maximum of eight wires
The screw does not need
to be removed completely
from the front panel
* If not already done
(see Section 2.5)
2. Feed in the cables and screw on the on-wall socket:
Feed the two-wire cable and the power supply unit (if
used) through the opening provided that is sealed with
a rubber plug. Use the 8-wire plug for the individual
wires. The other plugs with only one opening are ideally
suited to insulated, multi-wire cables of varying thickness. Now use the four Torx screws (item 1.6) to securely
fasten the on-wall socket to the screw anchors or directly
to the (wooden) surface. Please ensure that you only
use the existing four drill holes of the on-wall socket.
3. Remove the front panel and frame*: In order to protect
the Mx2wire+ circuit board, it is attached to the front
panel and frame in the original packaging. In order to
continue with the installation, however, you must first
separate the housing and circuit board (item 1.1) from
the panel and frame. Loosen the screw in the front
panel (item 1.2) and lift the panel forwards.
Now remove the attached frame from the circuit board.
Please note that you will need the stainless steel screw
in the front panel again later.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • sales@mobotix.com