3--10 CPU Specifications and Operation Setting the CPU Network Address The DL350 CPU has a built in DirectNET port. You can use the Handheld Programmer to set the network address for the port and the port communication parameters. The default settings are: S Station Address 1 S Hex Mode S Odd Parity S 9600 Baud The DirectNET Manual provides additional information about choosing the communication settings for network operation. Setting Retentive Memory Ranges The DL350 CPU provides certain ranges of retentive memory by default. The default ranges are suitable for many applications, but you can change them if your application requires additional retentive ranges or no retentive ranges at all. The default settings are: DL350 CPU Specifications and Operation Memory Area Default Range Avail. Range Control Relays C1000 -- C1777 C0 -- C1777 V--Memory V1400 -- V37777 V0 -- V37777 Timers None by default T0 -- T377 Counters CT0 -- CT177 CT0 -- CT177 Stages None by default S0 -- S1777 You can use AUX 57 to set the retentive ranges. You can also use DirectSOFT™ menus to select the retentive ranges. WARNING: The DL350 CPU does not come with a battery. The super capacitor will retain the values in the event of a power loss, but only for a short period of time, depending on conditions. If the retentive ranges are important for your application, make sure you obtain the optional battery. Password Protection The DL350 CPU allows you to use a password to help minimize the risk of unauthorized program and/or data changes. The DL350 offers multi--level passwords for even more security. Once you enter a password you can “lock” the CPU against access. Once the CPU is locked you must enter the password before you can use a programming device to change any system parameters. You can select an 8-digit numeric password. The CPUs are shipped from the factory with a password of 00000000. All zeros removes the password protection. If a password has been entered into the CPU you cannot enter all zeros to remove it. Once you enter the correct password, you can change the password to all zeros to remove the password protection. For more information on passwords, see Appendix A, Auxiliary Functions, Aux 8* -Password Operations. WARNING: Make sure you remember your password. If you forget your password you will not be able to access the CPU. The CPU must be returned to AutomationDirect to have the entire memory cleared in order to clear the password which is the policy of the AutomationDirect. DL350 User Manual, 2nd Edition