Download akta system - Sevier Lab

Transcript
Chapter 1
Introduction
This handbook, “ÄKTA Laboratory-scale Chromatography Systems,” is focused on liquid
chromatography systems used for protein purification at research laboratory scale. Beginners
can use the handbook to obtain an overview of how purification systems work and to learn
about important considerations for achieving successful results. Experienced system users will
also find valuable and detailed information on different hardware modules.
A chromatography system should be used when reproducible results are important and
when manual purification becomes too time-consuming and inefficient. Systems provide
more control than manual purification because of the ability to automatically control the flow
rate and monitor the progress of the purification as well as to make controlled gradients and
automatically collect fractions. Systems can perform automatic, simple, step-gradient elution
as well as high-resolution separations using accurately controlled linear-gradient elution.
This handbook addresses different aspects of ÄKTA chromatography systems, such as the effect
of system peak broadening on resolution, choosing sample injection technique, and selecting an
appropriate mixer. It also gives straightforward advice on how to avoid problems such as air
bubbles in the pump, how to troubleshoot problems such as high back pressure, and how to
perform cleaning of system components.
The appendices include a general introduction to the different ÄKTA laboratory-scale systems
and columns as well as information on how to determine exact delay volumes for a specific system.
Common acronyms and abbreviations
A280
AC
CF
CIP
CV
DS
FPLC™
GF
HIC
i.d. IMAC
IEX
mAU
MPa
mPas
o.d.
PM
RPC
Rs
s
SEC
UV/Vis
Absorbance of light at specified wavelength, in this example, 280 nanometers
Affinity chromatography
Chromatofocusing
Cleaning-in-place
Column volume
Desalting (group separation by gel filtration; buffer exchange)
Fast protein liquid chromatography
Gel filtration (sometimes referred to as SEC; size exclusion chromatography)
Hydrophobic interaction chromatography
Inner diameter
Immobilized metal affinity chromatography
Ion exchange chromatography (also seen as IEC in the literature)
Milli absorbance unit
MegaPascal; unit of pressure
Unit for viscosity (1 mPas = 1 cP, i.e., 1 centiPoise)
Outer diameter
Preventive maintenance
Reversed phase chromatography
Resolution, the degree of separation between peaks
Second(s)
Size exclusion chromatography (same as gel filtration)
Ultraviolet/visible light
29-0108-31 AA 5