Download akta system - Sevier Lab
Transcript
Chapter 1 Introduction This handbook, “ÄKTA Laboratory-scale Chromatography Systems,” is focused on liquid chromatography systems used for protein purification at research laboratory scale. Beginners can use the handbook to obtain an overview of how purification systems work and to learn about important considerations for achieving successful results. Experienced system users will also find valuable and detailed information on different hardware modules. A chromatography system should be used when reproducible results are important and when manual purification becomes too time-consuming and inefficient. Systems provide more control than manual purification because of the ability to automatically control the flow rate and monitor the progress of the purification as well as to make controlled gradients and automatically collect fractions. Systems can perform automatic, simple, step-gradient elution as well as high-resolution separations using accurately controlled linear-gradient elution. This handbook addresses different aspects of ÄKTA chromatography systems, such as the effect of system peak broadening on resolution, choosing sample injection technique, and selecting an appropriate mixer. It also gives straightforward advice on how to avoid problems such as air bubbles in the pump, how to troubleshoot problems such as high back pressure, and how to perform cleaning of system components. The appendices include a general introduction to the different ÄKTA laboratory-scale systems and columns as well as information on how to determine exact delay volumes for a specific system. Common acronyms and abbreviations A280 AC CF CIP CV DS FPLC™ GF HIC i.d. IMAC IEX mAU MPa mPas o.d. PM RPC Rs s SEC UV/Vis Absorbance of light at specified wavelength, in this example, 280 nanometers Affinity chromatography Chromatofocusing Cleaning-in-place Column volume Desalting (group separation by gel filtration; buffer exchange) Fast protein liquid chromatography Gel filtration (sometimes referred to as SEC; size exclusion chromatography) Hydrophobic interaction chromatography Inner diameter Immobilized metal affinity chromatography Ion exchange chromatography (also seen as IEC in the literature) Milli absorbance unit MegaPascal; unit of pressure Unit for viscosity (1 mPas = 1 cP, i.e., 1 centiPoise) Outer diameter Preventive maintenance Reversed phase chromatography Resolution, the degree of separation between peaks Second(s) Size exclusion chromatography (same as gel filtration) Ultraviolet/visible light 29-0108-31 AA 5