Download Numerical parameters
Transcript
Card BPG 4 – Numerical parameters 2/8 principle”: the solution should be accurate, with little diffusion, but it may exhibit values outside its physical limits) If the advected variables exhibit oscillations (in regions with high gradient values, stratification, distorted mesh…), it may be useful to use one of the following solutions, listed from the more accurate to the more robust: • Use the SOLU convection scheme: it is still second-order, but sometimes more stable than the centred scheme. • Use a blended convection scheme with a user-defined percentage of upwind (to begin with, one may prescribe 20% upwind, i.e. BLENCV=0.8). • Use an upwind scheme for all the advected variables (the result obtained this way will have to be considered as a first result, still to be improved). Flux reconstruction: the finite volume method relies on the calculation of convective and diffusive fluxes at the cell faces. These quantities are calculated from values of the variables evaluated at the orthogonal projections of the cell centres on the straight line normal to the face and containing its centre. By default, the method takes into account the fact that the mesh may not be orthogonal: the “flux reconstruction” is activated (IRCFLU=1). If this option is not used, the simulation is usually more stable but the discretization is not consistent any more (the solution converges as the mesh is refined, but it “sticks” to the mesh and is potentially wrong: for a diffusion problem, for example, the isolines are parallel to the mesh lines, independently of the physical phenomenon). Hence, it is generally compulsory to retain the flux reconstruction option. However, for RANS calculations and especially for the k-epsilon, it has been observed that switching off the flux reconstruction (IRCFLU=0) for k and epsilon could contribute to stabilizing the calculations when difficulties were encountered on low quality meshes, and this apparently without deteriorating the quality of the solution for the mean quantities. A priori, this also applies to the k-omega and all the other RANS variants 2 Pressure relaxation: for time marching schemes , it is possible to under-relax the pressure increments calculated within the pressure correction step (by default, no relaxation is used: RELAXV(IPR)=1.0). This is useful for distorted meshes and, a priori, it does not affect the quality of the solution. From previous experience, 30% is a reasonable value for the under-relaxation parameter (i.e. RELAXV(IPR)=0.7). For example, this option may be activated if the calculation fails after several time steps for which the number of iterations of the pressure iterative solver has been unusually large or if one suspects that the quality of the mesh is low in a region where large velocity values develop over a few time steps. Convergence threshold for the iterative solvers: it is not desirable to increase a priori and -8 -5 carelessly the threshold EPSILO (by default 10 , or 10 when the number of iterations for the right-8 hand-side reconstruction is large enough). However, 10 is a small value and it is possible to consider -5 using EPSILO=10 to save CPU time. For example, this choice may be made to produce a first approximation of the solution. One may also consider this choice if a large number of similar -5 computations must be carried out: the first computation may be run with EPSILO=10 and with -8 EPSILO=10 ; if the results are close enough, the rest of the simulations may then be carried out with -5 EPSILO=10 . Pressure interpolation: the pressure gradient is required at the cell centre for the momentum equation. Hence, because finite volume techniques are used, pressure face-values are necessary. Those are usually interpolated (centred interpolation) from values at the neighbouring cell-centres. This standard approach is appropriate as long as the pressure gradient is reasonably continuous. When the local variations of the pressure gradient are large, the approach is not valid any more (a simple centred interpolation cannot account for the fact that the pressure gradient is significantly 2 “Time marching scheme” is used here as opposed to “steady-state algorithm”.