Download User Manual ST10F272
Transcript
UM0381 Power reduction modes routine which can save the internal state into RAM. After the internal state has been saved, the trap routine may set a flag or write a certain bit pattern into specific RAM locations, and then execute the PWRDN instruction. If the NMI pin is still low at this time, power down mode will be entered, otherwise program execution continues. Exiting power down mode In this mode, the only way to exit power down mode is with an external hardware reset. The initialization routine (executed upon reset) can check the identification flag (see WDTCON - Section Section 14: Watchdog timer on page 290) or bit pattern within RAM to determine whether the controller was initially switched on, or whether it was properly restarted from Power Down mode. 24.2.2 Interruptible power down mode This mode is selected by setting the bit PWDCFG in register SYSCON to ‘1’. In this mode, the power down mode can be entered if enabled Fast External Interrupt pins (EXxIN pins, alternate functions of Port2 pins, with x = 7...0) are in their inactive level. This inactive level is configured with the EXIxES bit field in the EXICON register, as follow: EXICON (F1C0h / E0h) 15 14 13 12 ESFR 11 10 9 8 Reset Value: 0000h 7 6 5 4 3 2 1 0 EXI7ES EXI6ES EXI5ES EXI4ES EXI3ES EXI2ES EXI1ES EXI0ES RW RW RW RW RW RW RW RW Bit Function External Interrupt x Edge Selection Field (x = 7...0) 0 0: Fast external interrupts disabled: standard mode EXxIN pin not taken in account for entering/exiting Power Down mode. EXIxES (x = 7...0) 0 1: Interrupt on positive edge (rising) Enter power down mode if EXiIN = ‘0’, exit if EXxIN = ‘1’ (ref as ‘high’ active level) 1 0: Interrupt on negative edge (falling) Enter power down mode if EXiIN = ‘1’, exit if EXxIN = ‘0’ (ref as ‘low’ active level) 1 1: Interrupt on any edge (rising or falling) Always enter Power Down mode, exit if EXxIN level changed. Exiting power down mode When Interruptible power down mode is entered, the CPU and peripheral clocks are frozen, and the oscillator and PLL are stopped (when RTC is disabled, so there is no need for a clock reference). Interruptible power down mode can be exited by either asserting RSTIN or one of the enabled EXxIN pin (Fast External Interrupt). In case the Real Time Clock module needs to be running during Power Down, either the main or the low-power oscillator is not stopped. The PLL, on the contrary is nevertheless switched off. If power down mode is exited by a hardware RESET, RSTIN pin must be held low until the oscillator (if not already running for Real Time Clock operation) and PLL have restarted and stabilized. EXxIN inputs are normally sampled interrupt inputs. However, the power down mode circuitry uses them as level-sensitive inputs. An EXxIN (x = 7...0) Interrupt Enable bit (bit 479/537
Related documents
ST10F276
ST10 UART recommendations
“TOYUG”
TI Submission - TI E2E Community
Tektronix BERTScope Bit Error Ratio Analyzer & Pattern Generator
STMicroelectronics L4998 Datasheet
Blast-e manuals part1
User Manual - The Bodgery Wiki
UNIX
ST10F269 User's manual
Network Computing Devices, Inc. NCBridge Installation Manual for
The Other YN-622C User Guide