Download Blast-e manuals part1

Transcript
back
d.24 Delta f
No used
d.27 Tab_vhz
It enables the managing at closed ring of the SVC control
Set Value
Control selection
0
Open ring SVC
1
Closed ring SVC
7.3.4 I\O Parameters
To this category belong all the parameters proper of inputs and drive outputs (parameters of group
I and group O).
I.0 Polarity
Input/output polarity
Keypad value
1
2
4
8
16
32
256
512
Function
DIN 1 Active Low
DIN 2 Active Low
DIN 3 Active Low
DIN 4 Active Low
DIN 5 Active Low
DIN 6 Active Low
DOUT 1 Active Low
DOUT 2 Active Low
I1 ÷ I6: DIN1 ÷ DIN 6
Digital programming inputs.
Value set by
keypad
0
1
2
3
4
5
6
7
8
9
10
meaning
DISABILITATO
DRIVE ON CW
DRIVE ON CCW
Value set by
keypad
EN 1
11
12
13
14
EN 2
CW/CCW
SETPOINT UP
SETPOINT DOWN
JOG 1
JOG 2
JOG 3
15
16
17
18
19
20
21
meaning
SPEED/TORQUE
RESET ALARMS
DISABILITA RAMPE
SONDA TERMICA MOTORE (SOLO
DIN 1-4)
FREQUENCY INPUT ( SOLO DIN 5)
START CW
START CCW
SELECT – 0
SELECT – 1
SELECT – 2
OUT AN SELECTION
80