PCS 7 BRAUMAT Library - basic concepts Equipment module 1.4.2 Equipment phase For each EQM one CFC - chart is to be implemented. This chart should have the name of the EQM with the extension ‘_EPH’ (equipment module phase). The phase logic of the EQM is implemented primarily within an SFC-Type. The different functionality may be implemented as control strategies. 1.4.2.1 General Sequences Each SFC-Type has a standard structure consisting of the following sequences: ¾ Starting (only when necessary) ¾ Running ¾ Completing (for the most part used commonly for the ISA-88 states completing and aborting) ¾ Stopping (only when necessary) ¾ Holding ¾ Resuming Self terminating and non self - terminating phases ¾ PCS 7 BRAUMAT Library phases are implemented as self terminating or non self terminating phases according the technological demands. Target step number and target sequence number in SFC ¾ This feature is not used in the library. Unused sequences ¾ Unused sequences should be deleted. PCS 7 BRAUMAT Library V7.1 User Manual, 04/2012, A5E03447308-02 13