Manual – Prologger Hardware Model 7001D 8.2 Hardware Register Information The hardware register information can be viewed in Test Mode or used by programmers wishing to write their own unload and analysis programs. The table below gives a description of each register numbered 0 to 255. For multiple byte registers the convention used is . least significant byte to most significant byte. A byte may contain a number from 0 to 255 (8 bits) and for calculating multiple byte numbers the first byte is added to the second byte times 256 plus the third byte times 256 times 256, etc. eg. The four byte number 1234 would give: 1+(2*256)+(3*256*256)+(4*256*256*256) = 67305985 Arithmetic instructions using 32-bit unsigned integers can represent values from 0 to 4294967295. 8.2.1 Prologger Memory Assignments The Prologger operating the standard instruction set, has the following fixed memory assignments in the Hardware Register: (Pin xx) refers to a pin of the INPUT SIGNALS connector. Address Size Description 0 1 Software Revision Number (33 onwards) 1 2 logger runtime in milliseconds (16 bit integer) 3 1 Error flags (see Appendix A) 4 4 logger scan counter (32 bit integer) 8 3 Reserved 11 2 MSB of address (bits 8-23) used in LDBLK and MVBLK instructions 13 2 Reserved 14 2 Binary states of analog channels 16 8 Eight analog channels (a0 to a7) unsigned low resolution representation (8 bit) of the 16 bit channel (A0 to A7) measurement 24 8 Counter channels Unidata Manual - 7001D Prologger Hardware Issue 4.1.docx Page 31