Download GM 5000EA
Transcript
EDITION 03/2012 ORDER NUMBER DOC 2319149 GM 5000EA OPERATING MANUAL 5.5.3 CHANGING FROM AIR-ROUND JET TO AIR-FLAT JET #!54)/. $EFECTIVEELECTRODE -ATERIALDAMAGEDUETOFUNCTIONALFAULTS $ONOTDAMAGETHEELECTRODE 3)()??'" 1. 2. 3. 4. 5. 6. 7. 8. 9. Switch off the control unit. Relieve spray gun and unit pressure. Replace paint with cleaning solvent. Set material pressure. Switch off the atomizing air. Flush the spray gun out thoroughly. Relieve the material pressure on the spray gun and the devise! Unscrew nozzle nut (2) by hand. Remove AR 5000 air cap (3). Unscrew and remove AR 5000 nozzle (4) by hand. Clean the spray gun front page with dampened cloth carefully. Pay attention to the electrode (1). Use the protection cap for the valve needle (8). 10. Screw in and tighten slightly AF 5000 flat jet nozzle (6) by hand. 11. Put on the AF 5000 air cap (5). Screw the union nut (2) onto the spray gun body. 12. Set the desired flat jet level with the air cap horns (7) and then tighten slightly the union nut by hand. 3 4 2 7 1 2 5 6 8 5.5.4 CLEANING OF THE NOZZLE PARTS The nozzle parts (2; 3; 4; 5 and 6) may only be immersed into a cleaning solvent, recommended by the manufacturer and must be immediately removed again. They may not be loaded for a long time in cleaning solvent. Clean these parts with a brush and dry them with a cloth or a blow gun. B_03268 35