STINGER Specifications
STINGER
Compatible
Refrigerants
R-12, R-22, R-114, R-134a, R-401A, R-401B, R-401C, R-402A,
R-402B, R-404A, R-406A, R-407A, R-407B, R-407C, R-407D,
R-408A, R-409A, R-410A, R-411A, R-411B, R-412A, R-500,
R-502, R-507, R-509
Power
• 110/120 VAC, 1 Phase, 50/60 Hz, 8 Amps
• 230 VAC, 1 Phase, 50/60 Hz, 5 or 10 Amps
Compressor
¾ HP High Performance Oilless
Cooling
Two Cooling Fans
Protection
High pressure cutoff at 550 psi. Compressor is protected by
circuit breakers and internal compressor thermal sensor.
Optional 80% tank full shutoff kit (P/N 2090-0091).
Pressure
Ratings
Low Side design pressure 450 PSI
High Side design pressure 550 PSI
Temperature
Operating Range 32 to 104 °F (10 to 40 °C)
Case
Blow-Molded, High Impact Polyethylene
Size / Weight
Length
17"
Width
9.5"
Height
11"
Weight
28 Lbs.
Certification
See label on
back of unit
Complies with UL1963 (not evaluated for automotive use)
Refrigerant Recovery Rates
Certified per ARI 740-95 & 740-98
Refrigerant
R-22
R-134A
R-410A
Liquid Rate
Liquid Push-Pull
Rate
Vapor Rate
3.53 lb/min
1.60 kg/min
2.67 lb/min
1.21 kg/min
3.02 lb/min
1.37 kg/min
12.30 lb/min
5.58 kg/min
10.98 lb/min
4.98 kg/min
14.62 lb/min
6.63 kg/min
0.29 lb/min
0.13 kg/min
0.22 lb/min
0.10 kg/min
0.22 lb/min
0.10 kg/min
3
Vacuum Level
(inches Hg)
>15
>15
>15