If the programs say, “Tape drive not ready or not online” even though the drive is online. Make sure the controller card I/O software setting matches the jumper settings on the card. Remember, the jumpers on the controller card must match the settings for the software. Otherwise, the programs will not see the controller card. An I/O conflict will make it seem like the tape drive is broken. Change the I/O jumpers and run TACO to set the software. Jumper settings on the controller card The default I/O base address is 220H. If you need to change the I/O address of the card because the CUBS B M=250 32K H test does not run correctly, you should adjust the jumper settings as corresponding to the chart below and run TACO to set the software settings to conform to the jumper settings. Note that a 1 means the jumper is in place. A 0 means the jumper is off. Use the settings in the table below Powers of 2 5 6 7 8 HEX ADDRESS 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 200 220 240 260 280 2A0 2C0 2E0 300 320 340 360 380 3A0 3C0 3E0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 Factory setting Recommended second choice 13