Download WaveGuide - Direction User Manual
Transcript
2.3 Three cable connection Each cable between the server and a radar sensor, must be a shielded five wire cable with at least one twisted-wire-pair. The length of each cable can not exceed 1200 [m]. The cable shielding must be connected to ground at both ends of the cable. Since there can be a potential difference between the ground at the radar sensor side and the ground at the server side, a capacitor (10 to 100 [nF]) should be used on one side of the cable between its shield and the ground. The twisted-wire-pair is used for the RS-485 communication link (pins labeled 1 and 2). RS485 transceivers use differential signals and need a third wire to provide a reference common voltage to allow for the interpretation of the differential signal (pin labeled 3). Without this common reference, a set of transceivers may incorrectly interpret the differential signal. The remaining two wires out of the five wires in a cable are used for supplying power to the radar sensor (pins labeled + and -). Figure 2.3: The three cable connection diagram between the WaveGuide server and radars when the radars are powered from server. 13