Download AS-interface® components
Transcript
AS-interface) components CPV valve terminals without inputs, to SPEC V2.1 Technical data Type Part No. Code Valves AS-interface connection Load voltage connection LED displays General data AS-interface data 1) 2) 3) 24 CPV–…-GE-ASI-2-Z Number of valve slices/coils Valve width 10 mm 14 mm 18 mm Setting of the valve configuration External power supply 24 V DC Connection technology Voltage range [V DC] Residual ripple [mVss] Current consumption of all valves without current reduction [mA] with current reduction [mA] Connection technology Nominal voltage Residual ripple Max. starting current before current reduction following a current reduction PWR-LED FAULT-LED [V DC] [Vss] [mA] [mA] Valves Protection class (to EN 60 529) Electromagnetic compatibility Interference emission Interference immunity CE mark Temperature range [°C] Materials Dimensions Weight Pneumatic data ID code IO code ID2 code Profile Parameter P3 CPV valve diagnostic function Default Order via order code/valve terminal configurator AZ 2/4 n n n None (permanently assigned) Yes CPV–…-GE-ASI-4-Z1) AS/AZ 4/4 n n n CPV 10/14 Integrated DIL switch, CPV 183) Yes2) Set using DIL switch AS-interface flat cable plug (must be ordered separately) 26.5 … 31.6, reverse polarity protected 20 CPV10/14/18 CPV10/14/18 25/25/25 25/25/25 25/25/25 25/25/25 AS-interface flat cable plug (must be ordered separately) Blanking plug for sealing the unused connection enclosed 24 ±10% 4 CPV10/14/18 108/176/320 48/72/120 Power/green Fault LED/red CPV10/14/18 110/165/246 35/40/100 Peripherals fault LED/red Valve diagnostics: short circuit or wire break at valve solenoid coil, valve does not respond (no movement of the plunger) Yellow IP65 (fully assembled) Tested to EN 55011, limit value class B Tested to DIN EN 61000-4-2, DIN EN 61000-4-4 and EN V 50140 Yes, in accordance with EU Directive 89/336/EEC Operation: –5 … +50; storage/transport: –20 … +70 Housing: aluminium die-cast; cover: polyamide; seals: nitrile rubber, polychloroprene rubber è 26 è 26 è Info 213 Valve terminal CPV è Internet: cpv FH 8H FH EH (FH with CPV18) S-8.F S-8.F.E 1 = enable 2 = disable 1 for CPV with valve diagnostics New as of hardware status 0105: single or double solenoid valves can be configured by means of a DIL switch. With or without 24 V DC auxiliary power supply for solenoid coils (EMERGENCY-STOP circuitry). The auxiliary power supply is always integrated and can be switched on/off using the DIL switch. None (permanently assigned) è Internet: www.festo.com/catalog/... Subject to change – 2015/06