Download AS-interface® components

Transcript
AS-interface) components
CPV valve terminals without inputs, to SPEC V2.1
Technical data
Type
Part No.
Code
Valves
AS-interface
connection
Load voltage
connection
LED displays
General
data
AS-interface
data
1)
2)
3)
24
CPV–…-GE-ASI-2-Z
Number of valve slices/coils
Valve width
10 mm
14 mm
18 mm
Setting of the valve configuration
External power supply
24 V DC
Connection technology
Voltage range
[V DC]
Residual ripple
[mVss]
Current consumption of all valves
without current reduction [mA]
with current reduction
[mA]
Connection technology
Nominal voltage
Residual ripple
Max. starting current
before current reduction
following a current
reduction
PWR-LED
FAULT-LED
[V DC]
[Vss]
[mA]
[mA]
Valves
Protection class (to EN 60 529)
Electromagnetic compatibility
Interference emission
Interference immunity
CE mark
Temperature range
[°C]
Materials
Dimensions
Weight
Pneumatic data
ID code
IO code
ID2 code
Profile
Parameter P3
CPV valve diagnostic function
Default
Order via order code/valve terminal configurator
AZ
2/4
n
n
n
None (permanently assigned)
Yes
CPV–…-GE-ASI-4-Z1)
AS/AZ
4/4
n
n
n
CPV 10/14 Integrated DIL switch, CPV 183)
Yes2)
Set using DIL switch
AS-interface flat cable plug (must be ordered separately)
26.5 … 31.6, reverse polarity protected
20
CPV10/14/18
CPV10/14/18
25/25/25
25/25/25
25/25/25
25/25/25
AS-interface flat cable plug (must be ordered separately)
Blanking plug for sealing the unused connection
enclosed
24 ±10%
4
CPV10/14/18
108/176/320
48/72/120
Power/green
Fault LED/red
CPV10/14/18
110/165/246
35/40/100
Peripherals fault LED/red
Valve diagnostics: short circuit or wire break at
valve solenoid coil, valve does not respond (no
movement of the plunger)
Yellow
IP65 (fully assembled)
Tested to EN 55011, limit value class B
Tested to DIN EN 61000-4-2, DIN EN 61000-4-4 and EN V 50140
Yes, in accordance with EU Directive 89/336/EEC
Operation: –5 … +50; storage/transport: –20 … +70
Housing: aluminium die-cast; cover: polyamide; seals: nitrile rubber, polychloroprene rubber
è 26
è 26
è Info 213 Valve terminal CPV
è Internet: cpv
FH
8H
FH
EH (FH with CPV18)
S-8.F
S-8.F.E
1 = enable
2 = disable
1 for CPV with valve diagnostics
New as of hardware status 0105: single or double solenoid valves can be configured by means of a DIL switch.
With or without 24 V DC auxiliary power supply for solenoid coils (EMERGENCY-STOP circuitry). The auxiliary power supply is always integrated and can be switched on/off using the DIL switch.
None (permanently assigned)
è Internet: www.festo.com/catalog/...
Subject to change – 2015/06