Zone Errors
The SC6/12 is a sophisticated controller that will diagnose systems errors for you. The errors are reported on the
Auto/Run screen. There are two types of reported errors:
Zone Errors
- The zone number is displayed indicating one of the following problems:
A faulty or damaged solenoid valve resulting is excessively high or low current
A solenoid short circuit
A solenoid open circuit of broken wire (only reported if the zone has a valid run time)
Sensor Errors
- The sensor number is displayed indicating one of the following problems:
No communication between the controller and the sensor
A faulty or damaged sensor
Clear Errors
To clear the errors press the +/Clear button while in the Auto/Run screen. The controller will automatically clear the
errors when the problem is corrected. Any successful operation that shows that the error no longer applies will also
clear the error.