Download Roth MultiPex® Pipe System
Transcript
Roth Alu-LaserPlus® Pipe System Heat emission from Alu-LaserPlus® pipes. Please refer to DS 452 for requirements and standards. The Alu-LaserPlus® pipe has a good insulation capacity against heat emission and condensation when installing pipes-in-pipe as well as insulated pipes. Roth Alu-LaserPlus® pipe-in-pipe, free-standing 20 x 2,0 Roth Alu-LaserPlus® pipe-in-pipe, embedded in 50 mm concrete 20 x 2,0 16 x 2,0 26 x 2,0 16 x 2,0 26 x 2,0 Temperature difference (water - surroundings) ºC Temperature difference (water - surroundings) ºC Roth Alu-LaserPlus® pipe, insulated, free-standing Roth Alu-LaserPlus® pipe, insulated, embedded in 50 mm concrete 20 x 2,0 16 x 2,0 20 x 2,0 16 x 2,0 Temperature difference (water - surroundings) ºC Temperature difference (water - surroundings) ºC NOTE! When laying pipes free-standing without casing pipe compared with free-standing pipe-in-pipe, heat emission increases by approx. 30% 194 Roth Nordic Catalogue 2012-2013