Download DSPEC Pro
Transcript
794380D / 0914 1. INTRODUCTION Sample Changer Connections and Controls The DSPEC Pro connects easily to many types of automatic sample changer. Compact, Convenient Connectivity A small footprint means that the DSPEC Pro can sit right on the desktop. Lightweight but rugged, multiple units can be stacked on top of one another via their interlocking cases without fear of sliding or tipping. The easy-to-read, backlit LCD screen displays the instrument ID, name, preset count conditions, current live and real time, dead-time percentage (if active), input count rate, HV status and value, and, the serial number of SMART-1 detectors. Use a USB hub to quickly connect multiple instruments to your computer. ORTEC CONNECTIONS software supports any combination of USB devices (to a total of 127) connected to a particular computer. In addition, any number of other ORTEC multichannel buffers (USB and other interfaces) can be connected to the same system. Standard DSPEC-Family Features The DSPEC Pro also offers the InSight™ Virtual Oscilloscope, which allows you to optimize detector performance for a given application from the computer; our easy automatic pole-zero adjustment3 and automatic baseline restorer4; and the highly accurate Gedcke-Hale extended live-time correction method.5 1.2. Enhanced Throughput Mode To optimally process an input pulse stream, and thereby obtain the best spectral resolution, the signal processing device should allow the input signal to return to baseline before beginning to process the subsequent pulse. However, in cases where some loss of resolution is acceptable, it is possible for a DSP to begin processing a subsequent pulse before the first pulse has returned to the baseline, provided the first pulse has returned to baseline when the peak-detect of the second pulse occurs. The ORTEC Enhanced Throughput Mode takes advantage of this feature of digital signal processing by allowing you to adjust the delay between the peak-detect and the start of processing of the next pulse. The dead time for a conventionally processed pulse is the sum of the pulse’s rise time, flattop, and fall time. By contrast, the dead time in ORTEC’s Enhanced Throughput Mode can be as little as the rise time plus the flattop. These two scenarios are illustrated in Fig. 1. The DSPEC Pro lets you set a protection time (PT), following a peak-detect, that blocks 3 Patent number 5,872,363. 4 Patent number 5,912,825. 5 Ron Jenkins, R. W. Gould, and Dale Gedcke, Quantitative X-Ray Spectrometry (New York: Marcel Dekker, Inc.), 1981, pp. 266–267. 3