Download Complete - Tatsuno

Transcript
I N S T A L L A T I O N A N D
S A T E L L I T E D I S P E N S E R S
U S E R M A N U A L
- A P P E N D I X M
M.3.7. Data line distribution box scheme - XT15s
Chyba! Objekty nemohou být vytvořeny úpravami kódů polí.
Input
Output
Shielded Data Line Cable
Type:
CMFM 4D x 1.0 (recommended)
Connection: kiosk <---> XT15s
TX signal Tx
brown (hn)
RX signal Rx
light blue (sm)
AM signal Automat / Manual
black1 (c1)
0V signal ground
black2 (c2)
ST shield
shield (st)
1
2
TX
RX
AM
0V
ST
Shielded Data Line Cable
Type:
CMFM 4D x 0.5
Connection: XT15s <---> dispenser's counter
signal Tx
brown (hn)
signal Rx
light blue (sm)
signal Automat / Manual
black1 (c1)
signal ground
black2 (c2)
shield
shield (st)
Signal Cable
Signal Cable
Type:
CMSM 2A x 1.0 (recommended)
4
Type:
CMSM 2A x 0.5
Connection: satellite dispenser <---> XT15s
Connection: XT15s <---> dispenser's counter
NZ Satellite Nozzle Switch
brown (hn)
NZ Satellite Nozzle Switch
brown (hn)
0V Satellite Nozzle Switch
black (cr)
0V Satellite Nozzle Switch
black (cr)
Notes:
Distribution box type RK 002/6 is approved Ex II 2G EEx e II T6 with certificate FTZÚ 02 ATEX 0021. Inside box should
be usedonly clamps WAGO type 262-130 and 262-230, that are approved EEx e II. Maximum load of the one clamp is
10A/400V. Allowed wire cross-sections are in range from 0.5 to 2.5 mm2. Length of unisolated part of wire is min. 9 mm and
max.. 10 mm.
3
APPENDIX M / 12
Version: 2008-05-19