Download MOSFET Models
Transcript
MOSFET Models broadband segment and a CW segment. Set the broadband frequency list segment range at least as wide as the operating range of the device. Set the CW frequency segment to the frequency you intend to use for the data acquisition, the same frequency you set in the model variable table at the beginning of this procedure. This frequency should be above 200 MHz to eliminate the effects of test set coupler roll-off at low frequencies, and low enough to eliminate bond inductances and other parasitic inductance considerations. Based on the broadband cal, use a calibrated measurement point equal to the start frequency plus an integer multiple of the step size. An example frequency might be 600 MHz. 200 MHz (start freq)+1·400 MHz (step size)= 600 MHz Frequency List Calibration for an Agilent 8510Based System If you are using an Agilent 8510-based system, follow the steps below. 1. On the network analyzer press PRESET. 2. To define a linear frequency list, on the network analyzer press STIMULUS > MENU > MORE > EDIT LIST > ADD. A default frequency list segment is presented. 3. To change the segment to your chosen frequency range press SEGMENT: START, and use the numerical keypad to set the start frequency, ending with one of the terminator keys (such as M/μ) at the right of the keypad. Similarly, press STOP and set the stop frequency. Note Use the SEGMENT: START and STOP softkeys, not the START and STOP hardkeys in the STIMULUS area of the front panel. 4. Press SEGMENT: NUMBER of POINTS, and enter the number of frequency points to be measured across the range. Keep in mind that the fewer the number of points, the less time the measurements take. 5. Press DONE to return to the frequency list menu. The segment you just defined is listed on the screen. 6. Press DONE to return to the main stimulus menu. Press FREQUENCY LIST to activate the frequency list mode. 7. Press PRIOR MENU > MORE > CONTINUAL to set a continual stimulus sweep. 8. Press PRIOR MENU > POWER MENU, and set the desired power level. In setting the source power and attenuation, take care that the power level will not be excessive at the device input. Also consider the gain of the device, and set a power level that will not saturate the input port samplers of the analyzer. If the power level at the sampler goes above ≈-8 dBm, an *IF OVERLOAD* error message is displayed and you will need to reduce the source output power. The default network analyzer power level is 0 dBm. 9. For a device with power drop-off at higher frequencies, you may wish to set a power slope using the stimulus menus. An appropriate power slope would be in the region of 2-3 dB/GHz. 10. Press RESPONSE MENU > AVERAGING ON/restart, and enter an averaging factor high enough to reduce trace noise and increase dynamic range as appropriate for your device measurements. Although the default is 256, you may wish to use an averaging factor as low as 16 to reduce overall measurement time. 11. If the cal kit constants for your calibration kit are not loaded into the network analyzer, load them from disc now by pressing DISC > LOAD and specifying the data type and file name. 12. If you wish to modify one of the internal cal kit definitions, do so now. 13. Press CAL > CAL1 or CAL2 (depending on your cal kit), and perform a two-port calibration, measuring each of the standard devices in turn and pressing the softkeys as each measurement is complete. 14. At the end of the calibration sequence, the cal set numbers are listed in the softkey menu. Press CAL SET #1 to store the calibration in cal set #1. (Or use another available cal set.) CW Calibration Subset for an Agilent 8510Based System 1. To create a CW frequency subset of the broadband frequency list calibration, press CAL > CORRECTION ON > CAL SET 1 (this turns on the broadband cal you just completed), then MORE > MODIFY CAL SET > FREQUENCY SUBSET. Use the SUBSET: START and SUBSET: STOP softkeys in the SUBSET menu ( NOT the front panel keys) to set both start and stop to the same frequency. 2. Press CREATE & SAVE, and store this calibration in cal set #2 or another available cal set. 3. Note the numbers of the cal sets where you save the calibrations: you will need to list one of these numbers as part of the instrument state for each of the network analyzer measurements. Note For more detailed information, refer to the Agilent 8510 Operating and Programming Manual. Frequency List Calibration for an Agilent 8753Based System If you are using an Agilent 8753-based system, follow the steps below. 330