The front panel controls are arranged into three logical groups: HEADPHONE
MONITORING controls, STAND-ALONE controls, and input level controls.
The MONITOR switch allows the user to listen to either the MAIN INPUTS, the REF
INPUTS, or OUTPUTS signals with a pair of stereo headphones connected to either of the
two 1/4" PHONES jacks. The SELECT switch allows the user to listen to the signals in
STEREO, or to focus on either the LEFT or the RIGHT signal. Switching the MONITOR or
the SELECT switch does not alter the signal flow to the LEFT and RIGHT analog line
output BNC connectors. The VOLUME can be adjusted to a comfortable listening level.
The STAND-ALONE controls allow the user to select and run one of four previouslyprogrammed filter setups stored in internal nonvolatile memory. The OPERATION switch
must be set to STAND-ALONE for these special controls to become operational. For
complete instructions on using the STAND-ALONE memories, see Sections 4.9.4 and 5.
.0.
The OPERATION switch selects whether the unit is to be operated by the MCAP Master
Control program via RS232 interface to a PC (PC CONTROL setting) or in a stand-alone
configuration without a PC (STAND-ALONE setting). For complete instructions on using
the STAND-ALONE feature, see Sections 4.9.3 and 5. .0.
Note:
If the OPERATION switch is moved from STAND-ALONE to PC CONTROL while
the MCAP master control program is operating, the RS232 interface must be
reinitialized. Do so by clicking on the Settings in the menu bar and then on
Connect to Local MCAP.
The POWER switch must be switched to the ON position in order for the unit to operate.
The front panel of the MCAP external processor appears as follows (Figure 1-3):
Figure 1-3 MCAP Front Panel
The input level controls allow the user to adjust the input signals to the proper level for
STAND-ALONE processing (screen controls can be used when operating with a PC).
Tricolor LEDs are provided to indicate signal levels; when the LEDs are GREEN, the
signals are at the proper levels, while YELLOW indicates caution. RED indicates input
overload. Input signal levels are also indicated by the displayed bargraphs on the MCAP
Master Control Panel (See Section 4. ).
Page 4