FM581 Digital controlled DC-Motors amplifier
User Manual
12/10/11
Option
Description
RMP
Speed mode control and current mode control follow istantaneously every variation of the setpoint. This
option introduce the insertion of increment and decrement ramps between the setpoint and the
reference of the control loop. In current mode ramps are of current, in speed mode are of speed; in
booth cases the registers “Accel” and “Decel” contains the duration time of the ramp, starting from 0 up
to 100% (viceversa for deceleration).
0 => ramps disabled
1 => ramps enabled
FRR
At the general inhibit signal the drive can stop the motor in several ways, selected from this option and
the RMP.
0 => no brake, free-wheel stop
1 => ramp (RMP enabled) or braking with current limit for a maximum of 2 seconds of time
(RMP disabled).
NAC
At the startup, the drive executes a procedure of automatic calibration of the analog inputs of current
and voltage of the motor. If this happens while the shaft is completely stopped there is no problem, but
if the there is the possibility that the shaft is moving, it's necessary to disable the auto-calibration,
exactly with this option.
0 => analog input auto-calibration enabled
1 => analog input auto-calibration disabled
TKO
In speed mode with tachometer feedback, this option enables and disabled the alarm for a tacho
anomaly. Tachometer alarm identifies the following cases: tacho disconnected, tachometer (or cable)
shortcircuit, reverse connection.
0 => alarm disabled
1 => alarm enabled
MOC
Select the modality of operation, current or speed:
0 => speed mode
1 => current mode
FA1 FA0
Frequenza di
taglio
0
0
1KHz
0
1
500Hz
1
0
200Hz
1
1
disabled
This two bits select the cut frequency of the filter applied to the main analog input, or
disable the filter.