Download DCS-3010

Transcript
On the DC servo drive DCS-3010 can be connected encoder with single-ended outputs (A and B, Figure 4.3)
or encoder with differential (complementary) outputs (A+, A-, B+ and B- outputs, Figure 4.4). Encoder
interface SED1 at the A and B inputs has pull-up resistors of 4.7 kΩ.
DCS-3010
1
a)
8
Con.3
8p8c (RJ45)
Encoder interface
SED1
8p8c (RJ45)
GND B A +5V
1
8
GND
B
A
+5V
GND
B
A
+5V
encoder
Shilded
network cable
Cat 5e
DC
motor
DCS-3010
1
b)
8
Con.3
Shilded
network cable
Cat 5e
8p8c (RJ45)
Encoder interface
DD1
8p8c (RJ45)
1
8
encoder
GND
GND
BB+
AA+
+5V
B
A
+5V
DC
motor
Figure 4.3 Connection of single-ended encoder with DC servo drive DCS-3010 via,
a) SED1 encoder interface and b) DD1 encoder interface
DCS-3010
1
8
Con.3
8p8c (RJ45)
Oklopljeni
mrežni kabl
Cat 5e
Enkoder interfejs
DD1
8p8c (RJ45)
1
8
GND
BB+
AA+
+5V
GND
BB+
AA+
+5V
Figure 4.4 Connection of encoder with differential (complementary) outputs via DD1 encoder interface on
DC servo drive DCS-3010
Prizma doo, Kumanovska str. 8, 34000 Kragujevac, Serbia
Tel. +381 34 330 200, web: www.prizma.rs e-mail: prodaja@prizma.rs
Doc: DCS-3010 man Ver.1.07, January 2015. © by PRIZMA