Download Here - Delta Tau
Transcript
Accessory 24E2S MOTOR PARAMETER SETUP FOR UMAC AND MACRO The motor parameter setup is identical for both the Turbo PMAC and the Ultralite/MACRO Station systems. The key motor parameters to setup are the maximum pulse frequency output and the PID gains. Ix69 is the motor x output command limit for motor number x. For stepper motor systems, this parameter defines the magnitude of the largest number that may be placed into the PFM register for output pulse frequency. If the PMAC2 calculates a larger number than Ix69’s value, the number will be clipped to the limiting value and the result of a limited output value will be a larger following error. The default value appears to exceed most requirements for stepper motor applications, but the maximum pulse rate should be limited near the end of the setup process. The formula for setting Ix69 is: MasFrequency( KHz , MHz ) Ix69 PFMClock ( KHz , MHz x65536 The default setting for Ix69 is 20480 and the default PFM clock setting is set to approximately 9.8304 MHz. Using the default values and solving for Max Frequency, a maximum frequency output would be 3.0719 MHz. Putting a cap on the pulse output rate may keep the stepper system from exceeding its maximum step rate, which will help keep the motor from losing sync with the PMAC2. PMAC2 Motor Servo Gain I-Variables for Stepper Motors The PMAC2 applies its gain formulas for stepper motor systems the same way it does for a classic servo system. The basic difference with a stepper system is that the typical encoder feedback interface is handled using electronic circuitry rather than a physical encoder. The PMAC2 Stepper interface allows the use of both an electronic encoder feedback and/or physical encoder feedback (depending upon the hardware settings). When used with an actual physical encoder, the axis should be tuned as if it were a typical servo motor. The process of tuning the simulated feedback loop is identical to tuning a servo motor except that some of the parameters become more predictable: Ix30 Motor x Proportional Gain To create a closed loop position response with a natural frequency of approximately 25Hz and a damping ratio of 1, use the following calculation: Ix30 660000 Ix08 xPFMClock ( MHz ) Example: PFMCLK is set to default of 9.83 MHz, and Ix08 is set to default of 96. Ix30 = 660,000 / (96 * 9.83) = 700. Ix31 Motor x Derivative Gain Derivative Gain is set to 0 because the motor system behaves like a velocity-loop servo drive. This parameter sets the system damping which should be unnecessary. Ix32 Motor x Velocity Feedforward Gain Use the following equation to establish a value for Ix32: Ix32 6660 xServoFreq( kHz ) ServoFreq (kHz) is the frequency of the servo interrupt as established by I900, I901, and I902. Example: ServoFreq is set to default of 2.258 kHz (I900 = 6527, I901 = 0, I902 = 3). Ix32 = 6660 2.258 15,050. Motor Parameter Setup for UMAC and MACRO 25