Download wWARNING - Yamaha Robotics

Transcript
Thank you for purchasing this YAMAHA single-axis robot N15/N18.
Before using this robot, read the following notes and set the origin position.
The N15/N18 single-axis robots use absolute position detectors that do not require returnto-origin after turning on the controller power. However, when the controller power is
turned on in the following cases, return-to-origin must be performed just the very first
time.
(1) When robot cable was first connected after delivery from YAMAHA.
(2) When robot cable was disconnected from the controller and then reconnected.
(3) When no absolute battery is connected.
(4) When a motor or cable was replaced.
At this point, any of the following errors is issued immediately after controller power
is turned on, but this is not a malfunction. The controller will operate normally by
restarting.
When using an SRCX controller:
15 : FEEDBACK ERROR 2
23 : ABS.BAT.L-VOLTAGE
24 : ABS.DATA.ERROR
… etc.
When using an RCX142 controller:
17.81 : D?.ABS.battery wire breakage
17.92 : D?.Resolver disconnected during power off
17.93 : D?.Position backup counter overflow
… etc.
Before using the N15/N18 single-axis robots (Be sure to read the following notes.)
Before using the N15/N18 single-axis robots
(Be sure to read the following notes.)