Download Eclipse HX EHX Software User Guide - Clear-Com
Transcript
Limiter This sets the maximum audio level on the input that will be passed to further stages of the audio mixer. The limiter settings are: • Off • -6dB • -8db Threshold The threshold setting determines the level at which audio compression starts. When the audio input level passes the threshold it begins to be compressed so that the output level from the compressor approaches the audio limit more slowly as the audio input level rises. The threshold settings are: • Off • -10dB • -20dB Compressor The audio compressor reduces the audio level by compressing it whenever the audio level exceeds the threshold. Thishas the effect of allowing the audio level to rise but reducing it by a fixed ratio. The compressor settings are: • Off • Compression 5:1 • Compression 3:1 For example, if the compressor is set to 5:1 with a threshold of -10dB this will have the effect that for every 5dB increase in the input level above the threshold of -10dB the compressor will output only 1dB of increase. Thus if the input audio is 20dB above the threshold the output from the compressor will only show an increase of 4dB. If the limiter was set to +6dB then a 20dB increase would normally exceed the limiter (-10dB + 20dB = 10dB) so the audio level would be cut off at +6dB. With the compressor the audio level would not reach the limit so the audio would still rise to mimic the input (-10dB + 4dB = -6dB). Clear-Com® EHX User Guide 8-9