Download TimeSource 3500 GPS Primary Reference Source

Transcript
Chapter 4 TL1 Reference
Commands
Table 4-7. Retrieve Equipment Spec Block Parameters (Continued)
Aid
OPT-a
(990-720
50-06
systems
only)
Parameter
ALMOUT=b
FRAMING =b
OPT-a
(990-720
50-07
systems
only)
ALMOUT=b
FRAMING =b
146 TimeSource 3500 User’s Guide
Value
Parameter Description
b = AIS
Output is AIS during alarm
b = SQUELCH
Output is squelched during alarm
b = SSM
Outputs are at ‘STU’ quality level for ESF
framing and at ‘SSUT’ quality level for CAS4
and CCS4 framing during holdover alarm
(SSM requires CAS4, CCS4,or ESF output
framing)
b = CAS
Output framing is CAS
b = CAS4
Output framing is CAS4
b = CCS
Output framing is CCS
b = CCS4
Output framing is CCS4
b = D4
Output framing is D4
b = ESF
Output framing is ESF
b = NONE
Output framing is NONE (analog)
(If ALMOUT is SQUELCH, the signal turns
off during holdover alarm. Any other
ALMOUT option does not affect output
during alarm)
b = AIS
Output is AIS during alarm
b = SQUELCH
Output is squelched during alarm
b = SSM
Outputs are at ‘STU’ quality level during
holdover alarm (SSM requires ESF output
framing)
b = D4
Output framing is D4
b = ESF
Output framing is ESF
b = CCK
Output is Composite Clock. (ALMOUT is
SQUELCH by default and need not be
programmed. ALMOUT cannot be set to AIS
or SSM. The signal turns off during holdover
alarm.)
097-72050-01 Revision M – October, 2007