Download User manual
Transcript
1.GENERAL 1.1 Description The 20MHz/ 25MHz/ 3 0MHz/40 MHz/50MHz family oscilloscope are dual-channel oscilloscope with m aximum sensitivi ty of 5mV/D IV. The time base provides a m aximum sweep time of 0.2 uS /DIV. When magnified by 10, the sweep speed is 20nS/DIV. Each of these oscilloscope employs a 6-inch rectangular type cathode-ray t ube with red i nternal graticule. These oscilloscopes are sturdy, easy to operate and exhibits high operational reliability. 1.2 Features 1) High intensity CRT with high acceleration voltage: The CRT is a high beam transmission, high intensity type with a high acceleration voltage of 2KV for 20MHz/25MHz /30MHz and 12KV for 40MHz/50MH z.It displ ays clear readable traces even at high sweep speeds. 2) A trigger level lock function which makes the triggering adjustment unnecessary. 3) Alternate triggering: Even an observation of t wo waveforms of different frequencies, the waveform of the each channel is stably triggered. 4) TV sync triggering: The oscilloscope has a sync separator circuit for triggering of TV-V and TV-H signals. 5) X-Y operat ion: Set the swi tch to X-Y.Then the instrument works as an X -Y oscill oscope. CH l can be applied as horizontal deflection (X-axis) while C H2 provide verti cal deflection(Y-axis). 1 2. TECHNICAL SPECIFICATIONS MODEL SPECIFICATIONS S ensitiv ity Ve rnier Vertical sensit ivity Freque ncy ba ndwidth 20 MHz OSCILLOSCOPE 30MHz OSCILLOSCOPE 40MHz OSCILLOSCOPE 50MHz OSCILLOSCOPE 5mV ~5V/DIV,10 steps in 1-2-5 sequence To l/2.5 o r less of pan el-indicated value. DC~20MHz DC~30MH z DC~4 0MHz DC~50MHz AC coupling: Low limit frequency10Hz. (With reference to 100KHz, 8DIV. Frequency response with-3dB.) Rise tim e Inpu t impe dance DC balance shift Linearity Vertical m odes Appro x.17.5nS Appr ox.11.7 nS Appr ox.8.75 nS Approx .7nS Approx .lM ohm //App rox.25 pF Adjust able on panel ≤ ±0.l D IV of amplitude cha nge wh en wa vef o rm of 2 DIV at grat icule ce nter is move d verti cally. CH1 :CH l single channel. CH2 :CH 2 sing le cha nnel. DUAL :C H1 an d CH2 are displayed. ALT o r CHOP selec table at any sweep ra te. ADD:CH1+CH 2 algeb raic ad dition. Cho pping repetiti on freq uency Inp ut coupling M aximu m inpu t volta ge Approx. 250KH z AC, GND, DC 400V (D C+AC peak),AC:fre quency lKHz or lowe r. When se t probe switch at l:1, the max imum effecti ve read out is 4 0Vpp( 14Vrm s at sin e wave ), Com mon m ode re jection ratio Iso lation between chan nels (At 5m V/DIV range) CH2 INV BAL. 2 or set probe switch at 1 0:1,th e maxim um effective readou t is 40 0Vpp(1 40Vrm s at sin e wave). 50:1 or better a t 50KH z sinu soidal wave. (When sensit ivities of CH 1 and C H 2. a re set e qually ) > 1000:l at 50K Hz >3 0:l at 15M Hz >3 0:1 at 25 MHz >30:1 a t 35 MHz Balance d point variati on: ≤ 1 DIV( Refere nce at c enter graticu le.) >30:1 a t 45 MHz