Download User manual

Transcript
1.GENERAL
1.1 Description
The 20MHz/ 25MHz/ 3 0MHz/40 MHz/50MHz family oscilloscope are dual-channel oscilloscope with m aximum sensitivi ty
of 5mV/D IV. The time base provides a m aximum sweep time of 0.2 uS /DIV. When magnified by 10, the sweep speed is
20nS/DIV. Each of these oscilloscope employs a 6-inch rectangular type cathode-ray t ube with red i nternal graticule.
These oscilloscopes are sturdy, easy to operate and exhibits high operational reliability.
1.2 Features
1) High intensity CRT with high acceleration voltage:
The CRT is a high beam transmission, high intensity type with a high acceleration voltage of 2KV for 20MHz/25MHz
/30MHz and 12KV for 40MHz/50MH z.It displ ays clear readable traces even at high sweep speeds.
2) A trigger level lock function which makes the triggering adjustment unnecessary.
3) Alternate triggering:
Even an observation of t wo waveforms of different frequencies, the waveform of the each channel is stably triggered.
4) TV sync triggering:
The oscilloscope has a sync separator circuit for triggering of TV-V and TV-H signals.
5) X-Y operat ion:
Set the swi tch to X-Y.Then the instrument works as an X -Y oscill oscope. CH l can be applied as horizontal deflection
(X-axis) while C H2 provide verti cal deflection(Y-axis).
1
2. TECHNICAL SPECIFICATIONS
MODEL
SPECIFICATIONS
S ensitiv ity
Ve rnier Vertical sensit ivity
Freque ncy ba ndwidth
20 MHz OSCILLOSCOPE 30MHz OSCILLOSCOPE 40MHz OSCILLOSCOPE 50MHz OSCILLOSCOPE
5mV ~5V/DIV,10 steps in 1-2-5 sequence
To l/2.5 o r less of pan el-indicated value.
DC~20MHz
DC~30MH z
DC~4 0MHz
DC~50MHz
AC coupling: Low limit frequency10Hz. (With reference to 100KHz, 8DIV. Frequency response with-3dB.)
Rise tim e
Inpu t impe dance
DC balance shift
Linearity
Vertical m odes
Appro x.17.5nS
Appr ox.11.7 nS
Appr ox.8.75 nS
Approx .7nS
Approx .lM ohm //App rox.25 pF
Adjust able on panel
≤ ±0.l D IV of amplitude cha nge wh en wa vef o rm of 2 DIV at grat icule ce nter is move d verti cally.
CH1 :CH l single channel.
CH2 :CH 2 sing le cha nnel.
DUAL :C H1 an d CH2 are displayed. ALT o r CHOP selec table at any sweep ra te.
ADD:CH1+CH 2 algeb raic ad dition.
Cho pping repetiti on freq uency
Inp ut coupling
M aximu m inpu t volta ge
Approx. 250KH z
AC, GND, DC
400V (D C+AC peak),AC:fre quency lKHz or lowe r.
When se t probe switch at l:1, the max imum effecti ve read out is 4 0Vpp( 14Vrm s at sin e wave ),
Com mon m ode re jection ratio
Iso lation between chan nels
(At 5m V/DIV range)
CH2 INV BAL.
2
or set probe switch at 1 0:1,th e maxim um effective readou t is 40 0Vpp(1 40Vrm s at sin e wave).
50:1 or better a t 50KH z sinu soidal wave. (When sensit ivities of CH 1 and C H 2. a re set e qually )
> 1000:l at 50K Hz
>3 0:l
at 15M Hz
>3 0:1
at 25 MHz
>30:1
a t 35 MHz
Balance d point variati on: ≤ 1 DIV( Refere nce at c enter graticu le.)
>30:1
a t 45 MHz